All MIBs › SCTE-HMS-PROPERTY-MIB › analogAlarmHI
analogAlarmHI
Module: SCTE-HMS-PROPERTY-MIB
OID (symbolic): SCTE-HMS-PROPERTY-MIB::analogAlarmHI
OID (numeric): 1.3.6.1.4.1.5591.1.1.1.1.5
Node type: OBJECT-TYPE
Type: Integer32
Access: read-write
Description: The HI (Minor alarm)alarm occurs at this value. The unit associated with this property is the same as that of the parameter addressed. This object should be kept in NV memory.
Some devices only require 16 bit integer or smaller and therefore only support 16 bit (or smaller) values. Values outside of the supported range will return a bad value error.
What is analogAlarmHI?
This read-write Integer32 sets the threshold at which a HI, or minor, alarm is raised for the analog parameter that this propertyTable row is tracking. It lets an admin define an early-warning level below the HIHI major threshold, in the same units as the monitored value, and smaller devices with only 16-bit support may reject writes outside their range. For example, setting analogAlarmHI to 80 on a voltage-monitoring row flags a minor alarm once the voltage climbs past 80, well before the HIHI major threshold trips.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5591.1.1.1.1.5 snmpwalk -v2c -c public <target> SCTE-HMS-PROPERTY-MIB::analogAlarmHI
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.5591.1.1.1.1.5.1 snmpget -v2c -c public <target> SCTE-HMS-PROPERTY-MIB::analogAlarmHI.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.5591.1.1.1.1.5.1 i <value>
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> analogAlarmHI.1
Start monitoring cable/broadband HFC network element, transponder/line monitor/RF amplifier/fiber node/power supply (alarm-threshold property mechanism) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SCTE-HMS-PROPERTY-MIB::analogAlarmHI OID value, configure state conditions and alerts, and monitor any cable/broadband HFC network element, transponder/line monitor/RF amplifier/fiber node/power supply (alarm-threshold property mechanism) from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.5591 | scteRoot | SCTE-ROOT |
| 1.3.6.1.4.1.5591.1 | scteHmsTree | SCTE-ROOT |
| 1.3.6.1.4.1.5591.1.1 | propertyIdent | SCTE-HMS-ROOTS |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.5591.1.1.1 | propertyTable | SCTE-HMS-PROPERTY-MIB |
| 1.3.6.1.4.1.5591.1.1.1.1 | propertyEntry | SCTE-HMS-PROPERTY-MIB |
| 1.3.6.1.4.1.5591.1.1.1.1.5 | analogAlarmHI | SCTE-HMS-PROPERTY-MIB |