All MIBs › SCHLEIFENBAUER-DATABUS-MIB › sdbDevStMaximumTemperature
sdbDevStMaximumTemperature
Module: SCHLEIFENBAUER-DATABUS-MIB
OID (symbolic): SCHLEIFENBAUER-DATABUS-MIB::sdbDevStMaximumTemperature
OID (numeric): 1.3.6.1.4.1.31034.12.1.1.2.5.1.1.8
Node type: OBJECT-TYPE
Type: Integer32
Access: read-write
Description: Maximum temperature threshold An alert will be generated whenever the temperature is above this value. Zero means disabled.
What is sdbDevStMaximumTemperature?
Sets the temperature threshold, in degrees Celsius, above which the device raises a temperature alert; a value of 0 disables the check, so an admin should set a real threshold to get early warning of overheating.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.31034.12.1.1.2.5.1.1.8 snmpwalk -v2c -c public <target> SCHLEIFENBAUER-DATABUS-MIB::sdbDevStMaximumTemperature
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.31034.12.1.1.2.5.1.1.8.1 snmpget -v2c -c public <target> SCHLEIFENBAUER-DATABUS-MIB::sdbDevStMaximumTemperature.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.31034.12.1.1.2.5.1.1.8.1 i <value>
Start monitoring Schleifenbauer intelligent PDU, data center rack power distribution unit (databus ring topology health) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SCHLEIFENBAUER-DATABUS-MIB::sdbDevStMaximumTemperature OID value, configure state conditions and alerts, and monitor any Schleifenbauer intelligent PDU, data center rack power distribution unit (databus ring topology health) from a single console.
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.31034 | schleifenbauer | SCHLEIFENBAUER-SMI |
| 1.3.6.1.4.1.31034.12 | schleifenbauerMgmt | SCHLEIFENBAUER-SMI |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.31034.12.1 | schleifenbauerDatabusMIB | SCHLEIFENBAUER-DATABUS-MIB |
| 1.3.6.1.4.1.31034.12.1.1 | sdbMIBObjects | SCHLEIFENBAUER-DATABUS-MIB |
| 1.3.6.1.4.1.31034.12.1.1.2 | sdbDevice | SCHLEIFENBAUER-DATABUS-MIB |
| 1.3.6.1.4.1.31034.12.1.1.2.5 | sdbDevSettings | SCHLEIFENBAUER-DATABUS-MIB |
| 1.3.6.1.4.1.31034.12.1.1.2.5.1 | sdbDevStTable | SCHLEIFENBAUER-DATABUS-MIB |
| 1.3.6.1.4.1.31034.12.1.1.2.5.1.1 | sdbDevStEntry | SCHLEIFENBAUER-DATABUS-MIB |
| 1.3.6.1.4.1.31034.12.1.1.2.5.1.1.8 | sdbDevStMaximumTemperature | SCHLEIFENBAUER-DATABUS-MIB |