OID (symbolic): SCHLEIFENBAUER-DATABUS-MIB::sdbDevSsDeviceStatusCode

OID (numeric): 1.3.6.1.4.1.31034.12.1.1.2.3.1.1.1

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: Returns an internal status or error code. A value of 0 means OK. If not 0 it can be any of the following codes. Multiple status codes can be active at the same time. The value will be the sum of the active status codes.

1 = alert flagged 2 = settings(s) initialized 4 = power-on reset 8 = external reset 16 = watchdog timer caused reset 32 = brownout detected 64 = controller error 128 = slave module was reset

What is sdbDevSsDeviceStatusCode?

A bitmask internal status/error code for this device, where 0 means OK and any combination of bits (1=alert flagged, 2=settings initialized, 4=power-on reset, 8=external reset, 16=watchdog reset, 32=brownout, 64=controller error, 128=slave module reset) can be summed together, letting an admin diagnose exactly what has happened to the unit from a single value.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.31034.12.1.1.2.3.1.1.1
snmpwalk -v2c -c public <target> SCHLEIFENBAUER-DATABUS-MIB::sdbDevSsDeviceStatusCode

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.31034.12.1.1.2.3.1.1.1.1
snmpget -v2c -c public <target> SCHLEIFENBAUER-DATABUS-MIB::sdbDevSsDeviceStatusCode.1

Start monitoring Schleifenbauer intelligent PDU, data center rack power distribution unit (databus ring topology health) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SCHLEIFENBAUER-DATABUS-MIB::sdbDevSsDeviceStatusCode OID value, configure state conditions and alerts, and monitor any Schleifenbauer intelligent PDU, data center rack power distribution unit (databus ring topology health) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.31034schleifenbauerSCHLEIFENBAUER-SMI
1.3.6.1.4.1.31034.12schleifenbauerMgmtSCHLEIFENBAUER-SMI
Numeric OIDNameModule
1.3.6.1.4.1.31034.12.1schleifenbauerDatabusMIBSCHLEIFENBAUER-DATABUS-MIB
1.3.6.1.4.1.31034.12.1.1sdbMIBObjectsSCHLEIFENBAUER-DATABUS-MIB
1.3.6.1.4.1.31034.12.1.1.2sdbDeviceSCHLEIFENBAUER-DATABUS-MIB
1.3.6.1.4.1.31034.12.1.1.2.3sdbDevSystemStatusSCHLEIFENBAUER-DATABUS-MIB
1.3.6.1.4.1.31034.12.1.1.2.3.1sdbDevSsTableSCHLEIFENBAUER-DATABUS-MIB
1.3.6.1.4.1.31034.12.1.1.2.3.1.1sdbDevSsEntrySCHLEIFENBAUER-DATABUS-MIB
1.3.6.1.4.1.31034.12.1.1.2.3.1.1.1sdbDevSsDeviceStatusCodeSCHLEIFENBAUER-DATABUS-MIB