SCHLEIFENBAUER-DATABUS-MIB :: sdbDevOutMtKWhTotal

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › SCHLEIFENBAUER-DATABUS-MIB › sdbDevOutMtKWhTotal

sdbDevOutMtKWhTotal

Module: SCHLEIFENBAUER-DATABUS-MIB

OID (symbolic): SCHLEIFENBAUER-DATABUS-MIB::sdbDevOutMtKWhTotal

OID (numeric): 1.3.6.1.4.1.31034.12.1.1.2.7.2.1.2

Node type: OBJECT-TYPE

Type: KiloWattHour

Access: read-only

Description: Total kWh value of an outlet. This value can not be reset.

What is sdbDevOutMtKWhTotal?

The lifetime total energy consumed through this metered outlet, in kWh; this counter cannot be reset, making it a reliable long-term per-outlet energy record.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.31034.12.1.1.2.7.2.1.2
snmpwalk -v2c -c public <target> SCHLEIFENBAUER-DATABUS-MIB::sdbDevOutMtKWhTotal

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.31034.12.1.1.2.7.2.1.2.1
snmpget -v2c -c public <target> SCHLEIFENBAUER-DATABUS-MIB::sdbDevOutMtKWhTotal.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> sdbDevOutMtKWhTotal.1

Start monitoring Schleifenbauer intelligent PDU, data center rack power distribution unit (databus ring topology health) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SCHLEIFENBAUER-DATABUS-MIB::sdbDevOutMtKWhTotal OID value, configure state conditions and alerts, and monitor any Schleifenbauer intelligent PDU, data center rack power distribution unit (databus ring topology health) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.31034schleifenbauerSCHLEIFENBAUER-SMI
1.3.6.1.4.1.31034.12schleifenbauerMgmtSCHLEIFENBAUER-SMI
Numeric OIDNameModule
1.3.6.1.4.1.31034.12.1schleifenbauerDatabusMIBSCHLEIFENBAUER-DATABUS-MIB
1.3.6.1.4.1.31034.12.1.1sdbMIBObjectsSCHLEIFENBAUER-DATABUS-MIB
1.3.6.1.4.1.31034.12.1.1.2sdbDeviceSCHLEIFENBAUER-DATABUS-MIB
1.3.6.1.4.1.31034.12.1.1.2.7sdbDevOutletSCHLEIFENBAUER-DATABUS-MIB
1.3.6.1.4.1.31034.12.1.1.2.7.2sdbDevOutMtTableSCHLEIFENBAUER-DATABUS-MIB
1.3.6.1.4.1.31034.12.1.1.2.7.2.1sdbDevOutMtEntrySCHLEIFENBAUER-DATABUS-MIB
1.3.6.1.4.1.31034.12.1.1.2.7.2.1.2sdbDevOutMtKWhTotalSCHLEIFENBAUER-DATABUS-MIB