All MIBs › SAVEPOWER-MIB › hpicfSavepowerControl
hpicfSavepowerControl
Module: SAVEPOWER-MIB
OID (symbolic): SAVEPOWER-MIB::hpicfSavepowerControl
OID (numeric): 1.3.6.1.4.1.11.2.14.11.5.1.56.2.1.1.2
Node type: OBJECT-TYPE
Type: SavepowerControl
Access: read-write
Description: This indicates if the power to the block is powerOn (1) or powerOff (2).
What is hpicfSavepowerControl?
This read-write value controls whether a given power block - one row of the hpicfSavepowerTable, identified by hpicfSavepowerBlockID - is currently powerOn(1) or powerOff(2). Admins set it to physically cut or restore power to the group of ports covered by that block, typically to save energy on unused port groups. For example, setting hpicfSavepowerControl to powerOff(2) on a block covering unused ports 25-48 removes power from that entire port group.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.5.1.56.2.1.1.2 snmpwalk -v2c -c public <target> SAVEPOWER-MIB::hpicfSavepowerControl
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.5.1.56.2.1.1.2.1 snmpget -v2c -c public <target> SAVEPOWER-MIB::hpicfSavepowerControl.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.11.2.14.11.5.1.56.2.1.1.2.1 s <value>
Start monitoring HP Networking switching equipment, power saving (port-block power/LED scheduling) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SAVEPOWER-MIB::hpicfSavepowerControl OID value, configure state conditions and alerts, and monitor any HP Networking switching equipment, power saving (port-block power/LED scheduling) from a single console.
OID Breakdown
Upper-level ancestors (13 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.11 | hp | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2 | nm | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2.14 | icf | CONFIG-MIB |
| 1.3.6.1.4.1.11.2.14.11 | hpicfObjects | CONFIG-MIB |
| 1.3.6.1.4.1.11.2.14.11.5 | hpicfSwitch | CONFIG-MIB |
| 1.3.6.1.4.1.11.2.14.11.5.1 | hpSwitch | CONFIG-MIB |
| 1.3.6.1.4.1.11.2.14.11.5.1.56 | hpicfSavepowerMIB | HP-ICF-OID |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.11.2.14.11.5.1.56.2 | hpicfEntitySavepower | SAVEPOWER-MIB |
| 1.3.6.1.4.1.11.2.14.11.5.1.56.2.1 | hpicfSavepowerTable | SAVEPOWER-MIB |
| 1.3.6.1.4.1.11.2.14.11.5.1.56.2.1.1 | hpicfSavepowerEntry | SAVEPOWER-MIB |