SAF-INTEGRAX-MIB :: integraXsysPSUvoltage

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › SAF-INTEGRAX-MIB › integraXsysPSUvoltage

integraXsysPSUvoltage

Module: SAF-INTEGRAX-MIB

OID (symbolic): SAF-INTEGRAX-MIB::integraXsysPSUvoltage

OID (numeric): 1.3.6.1.4.1.7571.100.1.1.7.10.4.5

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: Power voltage in mV

What is integraXsysPSUvoltage?

Power supply output voltage in millivolts. A voltage sagging outside the expected rail (e.g. a 12V supply reading well under 12000 mV) is an early warning of a failing PSU before the unit actually browns out.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.7571.100.1.1.7.10.4.5
snmpwalk -v2c -c public <target> SAF-INTEGRAX-MIB::integraXsysPSUvoltage

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.7571.100.1.1.7.10.4.5.1
snmpget -v2c -c public <target> SAF-INTEGRAX-MIB::integraXsysPSUvoltage.1

Start monitoring SAF Tehnika Integra-X microwave radio link terminal (per-side RF configuration/temperature) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SAF-INTEGRAX-MIB::integraXsysPSUvoltage OID value, configure state conditions and alerts, and monitor any SAF Tehnika Integra-X microwave radio link terminal (per-side RF configuration/temperature) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.7571safSAF-ENTERPRISE
1.3.6.1.4.1.7571.100tehnikaSAF-ENTERPRISE
1.3.6.1.4.1.7571.100.1microwaveRadioSAF-ENTERPRISE
1.3.6.1.4.1.7571.100.1.1pointToPointSAF-ENTERPRISE
1.3.6.1.4.1.7571.100.1.1.7safIntegraSAF-INTEGRA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.7571.100.1.1.7.10integraXSAF-INTEGRAX-MIB
1.3.6.1.4.1.7571.100.1.1.7.10.4integraXsystemSAF-INTEGRAX-MIB
1.3.6.1.4.1.7571.100.1.1.7.10.4.5integraXsysPSUvoltageSAF-INTEGRAX-MIB