SAF-INTEGRAX-MIB :: integraXexecuteConfig

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › SAF-INTEGRAX-MIB › integraXexecuteConfig

integraXexecuteConfig

Module: SAF-INTEGRAX-MIB

OID (symbolic): SAF-INTEGRAX-MIB::integraXexecuteConfig

OID (numeric): 1.3.6.1.4.1.7571.100.1.1.7.10.6

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: This object can only be set to 1. It initiates new running configuration applying using values, that have been set before. Setting it when no new changes are available will do nothing and return an error. GET will return 0 if there were no errors, while executing configuration or will return a bitmask, that shows which SET requests have failed. Those failed requests will be shown bit wise from LSB as follows: BIT0 radioTxMuteDuration BIT1 radioTxFrequency BIT2 radioTxPower

What is integraXexecuteConfig?

Write-only trigger (execute(1) is the only accepted value) that applies a batch of configuration changes staged earlier via other SET requests. A subsequent GET returns 0 if the apply succeeded, or a bitmask (BIT0 radioTxMuteDuration, BIT1 radioTxFrequency, BIT2 radioTxPower) flagging exactly which staged SETs failed to apply.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.7571.100.1.1.7.10.6
snmpwalk -v2c -c public <target> SAF-INTEGRAX-MIB::integraXexecuteConfig

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.7571.100.1.1.7.10.6.1
snmpget -v2c -c public <target> SAF-INTEGRAX-MIB::integraXexecuteConfig.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.7571.100.1.1.7.10.6.1 i <value>

Start monitoring SAF Tehnika Integra-X microwave radio link terminal (per-side RF configuration/temperature) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SAF-INTEGRAX-MIB::integraXexecuteConfig OID value, configure state conditions and alerts, and monitor any SAF Tehnika Integra-X microwave radio link terminal (per-side RF configuration/temperature) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.7571safSAF-ENTERPRISE
1.3.6.1.4.1.7571.100tehnikaSAF-ENTERPRISE
1.3.6.1.4.1.7571.100.1microwaveRadioSAF-ENTERPRISE
1.3.6.1.4.1.7571.100.1.1pointToPointSAF-ENTERPRISE
1.3.6.1.4.1.7571.100.1.1.7safIntegraSAF-INTEGRA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.7571.100.1.1.7.10integraXSAF-INTEGRAX-MIB