SAF-INTEGRAW-MIB :: integraWexecuteConfig

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › SAF-INTEGRAW-MIB › integraWexecuteConfig

integraWexecuteConfig

Module: SAF-INTEGRAW-MIB

OID (symbolic): SAF-INTEGRAW-MIB::integraWexecuteConfig

OID (numeric): 1.3.6.1.4.1.7571.100.1.1.7.2.6

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: This object can only be set to 1. It initiates new running configuration applying using values, that have been set before. Setting it when no new changes are available will do nothing and return an error. GET will return 0 if there were no errors, while executing configuration or will return a bitmask, that shows which SET requests have failed. Those failed requests will be shown bit wise from LSB as follows: BIT0 radioTxMuteDuration BIT1 radioTxFrequency BIT2 radioTxPower

What is integraWexecuteConfig?

Is a read-write trigger, settable only to the value 'execute', that applies configuration changes already set via other SET requests into the running configuration; setting it again with no pending changes returns an error and does nothing. Reading it back returns 0 if the last apply succeeded, or a bitmask (bit0=Tx mute duration, bit1=Tx frequency, bit2=Tx power) identifying which specific settings failed to apply.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.7571.100.1.1.7.2.6
snmpwalk -v2c -c public <target> SAF-INTEGRAW-MIB::integraWexecuteConfig

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.7571.100.1.1.7.2.6.1
snmpget -v2c -c public <target> SAF-INTEGRAW-MIB::integraWexecuteConfig.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.7571.100.1.1.7.2.6.1 i <value>

Start monitoring SAF Tehnika IntegraW microwave radio link (transmit power/receive level/temperature) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SAF-INTEGRAW-MIB::integraWexecuteConfig OID value, configure state conditions and alerts, and monitor any SAF Tehnika IntegraW microwave radio link (transmit power/receive level/temperature) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.7571safSAF-ENTERPRISE
1.3.6.1.4.1.7571.100tehnikaSAF-ENTERPRISE
1.3.6.1.4.1.7571.100.1microwaveRadioSAF-ENTERPRISE
1.3.6.1.4.1.7571.100.1.1pointToPointSAF-ENTERPRISE
1.3.6.1.4.1.7571.100.1.1.7safIntegraSAF-INTEGRA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.7571.100.1.1.7.2integraWSAF-INTEGRAW-MIB
1.3.6.1.4.1.7571.100.1.1.7.2.6integraWexecuteConfigSAF-INTEGRAW-MIB