SAF-INTEGRAB-MIB :: integraBexecuteConfig

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › SAF-INTEGRAB-MIB › integraBexecuteConfig

integraBexecuteConfig

Module: SAF-INTEGRAB-MIB

OID (symbolic): SAF-INTEGRAB-MIB::integraBexecuteConfig

OID (numeric): 1.3.6.1.4.1.7571.100.1.1.7.1.6

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: This object can only be set to 1. It initiates new running configuration applying using values, that have been set before. Setting it when no new changes are available will do nothing and return an error. GET will return 0 if there were no errors, while executing configuration or will return a bitmask, that shows which SET requests have failed. Those failed requests will be shown bit wise from LSB as follows: BIT0 radioTxMuteDuration BIT1 radioTxFrequency BIT2 radioTxPower

What is integraBexecuteConfig?

A control object that can only be set to execute(1); doing so applies the running configuration built up from values already set via other writable objects. Setting it when there are no pending changes does nothing and returns an error. A subsequent GET returns 0 if the apply succeeded, or otherwise a bitmask flagging which specific pending SET requests failed (bit 0 = radioTxMuteDuration, bit 1 = radioTxFrequency, bit 2 = radioTxPower), which an admin uses to pinpoint exactly which change didn't take.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.7571.100.1.1.7.1.6
snmpwalk -v2c -c public <target> SAF-INTEGRAB-MIB::integraBexecuteConfig

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.7571.100.1.1.7.1.6.1
snmpget -v2c -c public <target> SAF-INTEGRAB-MIB::integraBexecuteConfig.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.7571.100.1.1.7.1.6.1 i <value>

Start monitoring SAF Tehnika Integra-B microwave radio link equipment (transmit power/receive level/temperature) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SAF-INTEGRAB-MIB::integraBexecuteConfig OID value, configure state conditions and alerts, and monitor any SAF Tehnika Integra-B microwave radio link equipment (transmit power/receive level/temperature) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.7571safSAF-ENTERPRISE
1.3.6.1.4.1.7571.100tehnikaSAF-ENTERPRISE
1.3.6.1.4.1.7571.100.1microwaveRadioSAF-ENTERPRISE
1.3.6.1.4.1.7571.100.1.1pointToPointSAF-ENTERPRISE
1.3.6.1.4.1.7571.100.1.1.7safIntegraSAF-INTEGRA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.7571.100.1.1.7.1integraBSAF-INTEGRAB-MIB