SAF-ALARM-MIB :: safAlarmActiveProbableCause

MIB Reference — IPNetwork Monitor · Updated September 21, 2026

All MIBs › SAF-ALARM-MIB › safAlarmActiveProbableCause

safAlarmActiveProbableCause

Module: SAF-ALARM-MIB

OID (symbolic): SAF-ALARM-MIB::safAlarmActiveProbableCause

OID (numeric): 1.3.6.1.4.1.7571.100.118.1.1.2.1.5

Node type: OBJECT-TYPE

Type: SafAlarmProbableCause

Access: read-only

Description: This parameter defines further qualification as to the probable cause of the alarm. Probable cause values for notifications shall be indicated in te behaviour clause of the object class definition. This parameter defines standard probables causes that have wide applicability across managed object classes.

What is safAlarmActiveProbableCause?

This object reports a standardized probable cause code for this alarm, drawn from a defined set of causes with broad applicability across different types of managed objects. Administrators use it to get a first indication of what likely caused the alarm without having to interpret the free-text description. For example, a probable cause value indicating a loss of signal would immediately point an admin toward a physical layer or cabling issue rather than a configuration problem.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.7571.100.118.1.1.2.1.5
snmpwalk -v2c -c public <target> SAF-ALARM-MIB::safAlarmActiveProbableCause

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.7571.100.118.1.1.2.1.5.1
snmpget -v2c -c public <target> SAF-ALARM-MIB::safAlarmActiveProbableCause.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> safAlarmActiveProbableCause.1

Start monitoring SAF Tehnika microwave radio transmission equipment (active alarm table/severity/timestamp) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SAF-ALARM-MIB::safAlarmActiveProbableCause OID value, configure state conditions and alerts, and monitor any SAF Tehnika microwave radio transmission equipment (active alarm table/severity/timestamp) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.7571safSAF-ENTERPRISE
1.3.6.1.4.1.7571.100tehnikaSAF-ENTERPRISE
Numeric OIDNameModule
1.3.6.1.4.1.7571.100.118safAlarmMIBSAF-ALARM-MIB
1.3.6.1.4.1.7571.100.118.1safAlarmObjectsSAF-ALARM-MIB
1.3.6.1.4.1.7571.100.118.1.1safAlarmActiveSAF-ALARM-MIB
1.3.6.1.4.1.7571.100.118.1.1.2safAlarmActiveTableSAF-ALARM-MIB
1.3.6.1.4.1.7571.100.118.1.1.2.1safAlarmActiveEntrySAF-ALARM-MIB
1.3.6.1.4.1.7571.100.118.1.1.2.1.5safAlarmActiveProbableCauseSAF-ALARM-MIB