RS366-OPT-MIB :: cdx6500RS366CfgMaxRespTime

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsRS366-OPT-MIBcdx6500RS366CfgMaxRespTime

cdx6500RS366CfgMaxRespTime

Module: RS366-OPT-MIB

OID (symbolic): RS366-OPT-MIB::cdx6500RS366CfgMaxRespTime

OID (numeric): 1.3.6.1.4.1.449.2.1.2.1.1.21.1.5

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Maximum EIA response time in seconds before a timeout can occur. sec0 - Indicates response time out should be disabled. sec32 - Maximum EIA response time is 32 seconds. sec48 - Maximum EIA response time is 48 seconds. sec96 - Maximum EIA response time is 96 seconds. newvalSec0 - same functionality as 'sec0', new enumeration added for RFC1155 compatibility.

What is cdx6500RS366CfgMaxRespTime?

cdx6500RS366CfgMaxRespTime sets the maximum EIA response time in seconds before a timeout occurs, with fixed choices of 0 (disabled), 32, 48, or 96 seconds, plus newvalSec0 as an RFC1155-compatible alias for disabling the timeout. Admins tune this to match how long the connected DCE/DTE equipment may legitimately take to respond, balancing fast failure detection against false timeouts on slower equipment. For example, setting cdx6500RS366CfgMaxRespTime to sec96(96) gives slow-responding dial equipment more time before the port declares a timeout.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.449.2.1.2.1.1.21.1.5
snmpwalk -v2c -c public <target> RS366-OPT-MIB::cdx6500RS366CfgMaxRespTime

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.449.2.1.2.1.1.21.1.5.1
snmpget -v2c -c public <target> RS366-OPT-MIB::cdx6500RS366CfgMaxRespTime.1

Start monitoring cdx6500-series serial/dial interface equipment (RS-366 auto-call dial port configuration) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the RS366-OPT-MIB::cdx6500RS366CfgMaxRespTime OID value, configure state conditions and alerts, and monitor any cdx6500-series serial/dial interface equipment (RS-366 auto-call dial port configuration) from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.449codexALC-OPT-MIB
1.3.6.1.4.1.449.2cdxProductSpecificALC-OPT-MIB
1.3.6.1.4.1.449.2.1cdx6500ALC-OPT-MIB
1.3.6.1.4.1.449.2.1.2cdx6500ConfigurationALC-OPT-MIB
1.3.6.1.4.1.449.2.1.2.1cdx6500CfgProtocolGroupALC-OPT-MIB
1.3.6.1.4.1.449.2.1.2.1.1cdx6500PCTPortProtocolGroupALC-OPT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.449.2.1.2.1.1.21cdx6500PPCTRS366PortTableRS366-OPT-MIB
1.3.6.1.4.1.449.2.1.2.1.1.21.1cdx6500PPCTRS366PortEntryRS366-OPT-MIB
1.3.6.1.4.1.449.2.1.2.1.1.21.1.5cdx6500RS366CfgMaxRespTimeRS366-OPT-MIB