RFC1317-MIB :: rs232SyncPortAbortedFrames

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsRFC1317-MIBrs232SyncPortAbortedFrames

rs232SyncPortAbortedFrames

Module: RFC1317-MIB

OID (symbolic): RFC1317-MIB::rs232SyncPortAbortedFrames

OID (numeric): 1.3.6.1.2.1.10.33.4.1.7

Node type: OBJECT-TYPE

Type: Counter

Access: read-only

Description: Number of frames aborted on the port due to receiving an abort sequence since system re-initialization and while the port state was 'up' or 'test'.

What is rs232SyncPortAbortedFrames?

Running count of frames aborted on this synchronous port because an abort sequence was received, counted since the last system re-initialization while the port state was up or test.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.2.1.10.33.4.1.7
snmpwalk -v2c -c public <target> RFC1317-MIB::rs232SyncPortAbortedFrames

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.2.1.10.33.4.1.7.1
snmpget -v2c -c public <target> RFC1317-MIB::rs232SyncPortAbortedFrames.1

Start monitoring vendor-neutral, standards-based MIB, terminal/console servers and routers with RS-232 serial ports with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the RFC1317-MIB::rs232SyncPortAbortedFrames OID value, configure state conditions and alerts, and monitor any vendor-neutral, standards-based MIB, terminal/console servers and routers with RS-232 serial ports from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.2mgmtAXON-MIB
1.3.6.1.2.1mib_2AXON-MIB
1.3.6.1.2.1.10transmissionCHECKPOINT-MIB-2
1.3.6.1.2.1.10.33rs232MRVINREACH
1.3.6.1.2.1.10.33.4rs232SyncPortTableMRVINREACH
1.3.6.1.2.1.10.33.4.1rs232SyncPortEntryMRVINREACH
Numeric OIDNameModule
1.3.6.1.2.1.10.33.4.1.7rs232SyncPortAbortedFramesRFC1317-MIB