RBN-CPU-METER-MIB :: rbnCpuProcTime

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › RBN-CPU-METER-MIB › rbnCpuProcTime

rbnCpuProcTime

Module: RBN-CPU-METER-MIB

OID (symbolic): RBN-CPU-METER-MIB::rbnCpuProcTime

OID (numeric): 1.3.6.1.4.1.2352.2.6.3.1.1.3

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: The total time, in milliseconds, that has been spent in this process.

What is rbnCpuProcTime?

Counts the total time, in milliseconds, that the CPU has spent executing a given process. Admins compare this counter across processes to identify which one is consuming the most cumulative CPU time. A process whose rbnCpuProcTime is climbing much faster than its peers points to it as the primary CPU consumer.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2352.2.6.3.1.1.3
snmpwalk -v2c -c public <target> RBN-CPU-METER-MIB::rbnCpuProcTime

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2352.2.6.3.1.1.3.1
snmpget -v2c -c public <target> RBN-CPU-METER-MIB::rbnCpuProcTime.1

Start monitoring Redback Networks BRAS platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the RBN-CPU-METER-MIB::rbnCpuProcTime OID value, configure state conditions and alerts, and monitor any Redback Networks BRAS platforms from a single console.

How to Use in IPNetwork Monitor

Select a Redback Networks BRAS platform as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type rbnCpuProcTime into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The total time, in milliseconds, that has been spent in this process. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if utilization exceeds 85%, a common warning threshold before sustained high load affects performance. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2352redBackNetworksRBN-SMI
1.3.6.1.4.1.2352.2rbnMgmtRBN-SMI
Numeric OIDNameModule
1.3.6.1.4.1.2352.2.6rbnCpuMeterMIBRBN-CPU-METER-MIB
1.3.6.1.4.1.2352.2.6.3rbnCpuProcMIBObjectsRBN-CPU-METER-MIB
1.3.6.1.4.1.2352.2.6.3.1rbnCpuProcTableRBN-CPU-METER-MIB
1.3.6.1.4.1.2352.2.6.3.1.1rbnCpuProcEntryRBN-CPU-METER-MIB
1.3.6.1.4.1.2352.2.6.3.1.1.3rbnCpuProcTimeRBN-CPU-METER-MIB