RAISECOM-ELPS-MIB :: rcElpsManualSwitchtoWork

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › RAISECOM-ELPS-MIB › rcElpsManualSwitchtoWork

rcElpsManualSwitchtoWork

Module: RAISECOM-ELPS-MIB

OID (symbolic): RAISECOM-ELPS-MIB::rcElpsManualSwitchtoWork

OID (numeric): 1.3.6.1.4.1.8886.6.1.54.1.2.1.11

Node type: OBJECT-TYPE

Type: TruthValue

Access: read-write

Description: In the absence of a failure of a working or protection transport entity in non-revertive operation, forces normal traffic signal to be selected from the working transport entity.

What is rcElpsManualSwitchtoWork?

Writing TRUE requests traffic be switched back to the working transport entity in non-revertive mode when neither entity has failed, letting an admin manually restore traffic to the primary path after a manual switch to protection.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.8886.6.1.54.1.2.1.11
snmpwalk -v2c -c public <target> RAISECOM-ELPS-MIB::rcElpsManualSwitchtoWork

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.8886.6.1.54.1.2.1.11.1
snmpget -v2c -c public <target> RAISECOM-ELPS-MIB::rcElpsManualSwitchtoWork.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.8886.6.1.54.1.2.1.11.1 s <value>

Start monitoring Raisecom metro/carrier Ethernet switch, media converter/access device (ITU-T G.8031 linear protection) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the RAISECOM-ELPS-MIB::rcElpsManualSwitchtoWork OID value, configure state conditions and alerts, and monitor any Raisecom metro/carrier Ethernet switch, media converter/access device (ITU-T G.8031 linear protection) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.8886raisecomRAISECOM-BASE-MIB
1.3.6.1.4.1.8886.6iscomSeriesRAISECOM-BASE-MIB
1.3.6.1.4.1.8886.6.1iscomSwitchRAISECOM-BASE-MIB
Numeric OIDNameModule
1.3.6.1.4.1.8886.6.1.54rcElpsRAISECOM-ELPS-MIB
1.3.6.1.4.1.8886.6.1.54.1rcElpsBaseGroupRAISECOM-ELPS-MIB
1.3.6.1.4.1.8886.6.1.54.1.2rcElpsCfgTableRAISECOM-ELPS-MIB
1.3.6.1.4.1.8886.6.1.54.1.2.1rcElpsCfgEntryRAISECOM-ELPS-MIB
1.3.6.1.4.1.8886.6.1.54.1.2.1.11rcElpsManualSwitchtoWorkRAISECOM-ELPS-MIB