RADLAN-AAA :: rlTacacsServerTimeout

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › RADLAN-AAA › rlTacacsServerTimeout

rlTacacsServerTimeout

Module: RADLAN-AAA

OID (symbolic): RADLAN-AAA::rlTacacsServerTimeout

OID (numeric): 1.3.6.1.4.1.89.79.40.7.1.5

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: The maximum time (in seconds) to wait for this TACACS+ server to reply. Value of 0 means that rlTacacsGlobalDefaultTimeout value is used.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.89.79.40.7.1.5
snmpwalk -v2c -c public <target> RADLAN-AAA::rlTacacsServerTimeout

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.89.79.40.7.1.5.1
snmpget -v2c -c public <target> RADLAN-AAA::rlTacacsServerTimeout.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.89.79.40.7.1.5.1 i <value>

Start monitoring Radlan/Marvell-chipset managed switch, various OEM brands (AAA configuration) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the RADLAN-AAA::rlTacacsServerTimeout OID value, configure state conditions and alerts, and monitor any Radlan/Marvell-chipset managed switch, various OEM brands (AAA configuration) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.89rndDell-MIB
1.3.6.1.4.1.89.79rlAAADell-AAA
1.3.6.1.4.1.89.79.40rlTacacsDell-AAA
1.3.6.1.4.1.89.79.40.7rlTacacsServerTableDell-AAA
1.3.6.1.4.1.89.79.40.7.1rlTacacsServerEntryDell-AAA
Numeric OIDNameModule
1.3.6.1.4.1.89.79.40.7.1.5rlTacacsServerTimeoutRADLAN-AAA