RADLAN-AAA :: rlAAALineConsFailedLogins

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › RADLAN-AAA › rlAAALineConsFailedLogins

rlAAALineConsFailedLogins

Module: RADLAN-AAA

OID (symbolic): RADLAN-AAA::rlAAALineConsFailedLogins

OID (numeric): 1.3.6.1.4.1.89.79.16.1.22

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: Number of last consecutive failed logins

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.89.79.16.1.22
snmpwalk -v2c -c public <target> RADLAN-AAA::rlAAALineConsFailedLogins

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.89.79.16.1.22.1
snmpget -v2c -c public <target> RADLAN-AAA::rlAAALineConsFailedLogins.1

Start monitoring Radlan/Marvell-chipset managed switch, various OEM brands (AAA configuration) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the RADLAN-AAA::rlAAALineConsFailedLogins OID value, configure state conditions and alerts, and monitor any Radlan/Marvell-chipset managed switch, various OEM brands (AAA configuration) from a single console.

How to Use in IPNetwork Monitor

Select a Radlan/Marvell-chipset managed switch, various OEM brand (AAA configuration) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type rlAAALineConsFailedLogins into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. It reports the number of last consecutive failed logins. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases between polls, since a rising count of errors, failures, or discards often points to a real underlying problem. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.89rndDell-MIB
1.3.6.1.4.1.89.79rlAAADell-AAA
1.3.6.1.4.1.89.79.16rlAAALineTableDell-AAA
1.3.6.1.4.1.89.79.16.1rlAAALineEntryDell-AAA
Numeric OIDNameModule
1.3.6.1.4.1.89.79.16.1.22rlAAALineConsFailedLoginsRADLAN-AAA