RAD-HDLC-MIB :: hdlcLOF

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › RAD-HDLC-MIB › hdlcLOF

hdlcLOF

Module: RAD-HDLC-MIB

OID (symbolic): RAD-HDLC-MIB::hdlcLOF

OID (numeric): 1.3.6.1.4.1.164.3.1.6.5.1.1.10

Node type: OBJECT-TYPE

Type: Gauge32

Access: read-only

Description: Total number of seconds the port is in Loss Of Frame state.

What is hdlcLOF?

Reports the total number of seconds the port has spent in a Loss Of Frame condition; a nonzero and growing value points at a framing problem on the physical circuit that an admin should chase down before it causes an outage.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.164.3.1.6.5.1.1.10
snmpwalk -v2c -c public <target> RAD-HDLC-MIB::hdlcLOF

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.164.3.1.6.5.1.1.10.1
snmpget -v2c -c public <target> RAD-HDLC-MIB::hdlcLOF.1

Start monitoring RAD Data Communications HDLC WAN access equipment with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the RAD-HDLC-MIB::hdlcLOF OID value, configure state conditions and alerts, and monitor any RAD Data Communications HDLC WAN access equipment from a single console.

How to Use in IPNetwork Monitor

Select a RAD Data Communications HDLC WAN access equipment as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type hdlcLOF into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. It reports the total number of seconds the port is in Loss Of Frame state. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Gauge32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.164radDACS-MIB
1.3.6.1.4.1.164.3radWanDACS-MIB
1.3.6.1.4.1.164.3.1wanGenDACS-MIB
1.3.6.1.4.1.164.3.1.6diverseIfWanGenDACS-MIB
Numeric OIDNameModule
1.3.6.1.4.1.164.3.1.6.5hdlcMibObjectsRAD-HDLC-MIB
1.3.6.1.4.1.164.3.1.6.5.1hdlcTableRAD-HDLC-MIB
1.3.6.1.4.1.164.3.1.6.5.1.1hdlcEntryRAD-HDLC-MIB
1.3.6.1.4.1.164.3.1.6.5.1.1.10hdlcLOFRAD-HDLC-MIB