PT-SFP-MIB :: length50m10m

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › PT-SFP-MIB › length50m10m

length50m10m

Module: PT-SFP-MIB

OID (symbolic): PT-SFP-MIB::length50m10m

OID (numeric): 1.3.6.1.4.1.193.223.2.6.1.1.17

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: Link length supported for 50/125 um OM2 fiber, units of 10 m

What is length50m10m?

The maximum link length, in units of 10 meters, this transceiver supports over 50/125 um OM2 multimode fiber. An admin checks this against the actual OM2 fiber run to confirm the optic can reach the far end before installing it.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.193.223.2.6.1.1.17
snmpwalk -v2c -c public <target> PT-SFP-MIB::length50m10m

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.193.223.2.6.1.1.17.1
snmpget -v2c -c public <target> PT-SFP-MIB::length50m10m.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> length50m10m.1

Start monitoring Ericsson PT (packet transport) equipment (SFP transceiver inventory) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the PT-SFP-MIB::length50m10m OID value, configure state conditions and alerts, and monitor any Ericsson PT (packet transport) equipment (SFP transceiver inventory) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.193ericssonANS-COMMON-MIB
1.3.6.1.4.1.193.223miniLinkMINI-LINK-MIB
1.3.6.1.4.1.193.223.2ptPT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.193.223.2.6ptSFPPT-SFP-MIB
1.3.6.1.4.1.193.223.2.6.1ptSFPTablePT-SFP-MIB
1.3.6.1.4.1.193.223.2.6.1.1ptSFPEntryPT-SFP-MIB
1.3.6.1.4.1.193.223.2.6.1.1.17length50m10mPT-SFP-MIB