PRVT-RESILIENT-LINK-MIB :: resilientLinkEnable

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › PRVT-RESILIENT-LINK-MIB › resilientLinkEnable

resilientLinkEnable

Module: PRVT-RESILIENT-LINK-MIB

OID (symbolic): PRVT-RESILIENT-LINK-MIB::resilientLinkEnable

OID (numeric): 1.3.6.1.4.1.738.1.5.102.1.1.1.2

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: This object enables or disables the resilient link

What is resilientLinkEnable?

This read-write value enables or disables a resilient link, the redundant dual-port pairing identified by resilientLinkIndex. Admins turn a resilient link on to activate automatic failover between its two member ports, or off to stop treating those ports as a redundant pair. For example, setting resilientLinkEnable to disable(2) stops the device from failing over between the link's two ports.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.738.1.5.102.1.1.1.2
snmpwalk -v2c -c public <target> PRVT-RESILIENT-LINK-MIB::resilientLinkEnable

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.738.1.5.102.1.1.1.2.1
snmpget -v2c -c public <target> PRVT-RESILIENT-LINK-MIB::resilientLinkEnable.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.738.1.5.102.1.1.1.2.1 i <value>

Start monitoring BATM Advanced Communication switch (primary/backup uplink failover) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the PRVT-RESILIENT-LINK-MIB::resilientLinkEnable OID value, configure state conditions and alerts, and monitor any BATM Advanced Communication switch (primary/backup uplink failover) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.738privateVendorOIDPRIV-VENDORDEF-MIB
1.3.6.1.4.1.738.1prvt_productsPRVT-SWITCH-MIB
1.3.6.1.4.1.738.1.5switchPRVT-SWITCH-MIB
Numeric OIDNameModule
1.3.6.1.4.1.738.1.5.102prvtResilientLinkMibPRVT-RESILIENT-LINK-MIB
1.3.6.1.4.1.738.1.5.102.1resilientLinkConfigPRVT-RESILIENT-LINK-MIB
1.3.6.1.4.1.738.1.5.102.1.1resilientLinkConfigTablePRVT-RESILIENT-LINK-MIB
1.3.6.1.4.1.738.1.5.102.1.1.1resilientLinkConfigEntryPRVT-RESILIENT-LINK-MIB
1.3.6.1.4.1.738.1.5.102.1.1.1.2resilientLinkEnablePRVT-RESILIENT-LINK-MIB