PRVT-PW-TDM-MIB :: prvtPwVcTDMPerfIntervalDuration

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsPRVT-PW-TDM-MIBprvtPwVcTDMPerfIntervalDuration

prvtPwVcTDMPerfIntervalDuration

Module: PRVT-PW-TDM-MIB

OID (symbolic): PRVT-PW-TDM-MIB::prvtPwVcTDMPerfIntervalDuration

OID (numeric): 1.3.6.1.4.1.738.1.5.200.2.1.6.1.3

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: The duration of a particular interval in seconds, Adjustments in the system's time-of-day clock, may cause the interval to be greater or less than, the normal value. Therefore this actual interval value is provided.

What is prvtPwVcTDMPerfIntervalDuration?

Reports the actual duration, in seconds, of this historical performance interval, which can differ from the nominal 15 minutes if the system clock was adjusted. Admins use this to correctly normalize rate calculations from the interval's raw counters.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.738.1.5.200.2.1.6.1.3
snmpwalk -v2c -c public <target> PRVT-PW-TDM-MIB::prvtPwVcTDMPerfIntervalDuration

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.738.1.5.200.2.1.6.1.3.1
snmpget -v2c -c public <target> PRVT-PW-TDM-MIB::prvtPwVcTDMPerfIntervalDuration.1

Start monitoring BATM Advanced Communications circuit emulation/pseudowire gateway (TDM-over-packet) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the PRVT-PW-TDM-MIB::prvtPwVcTDMPerfIntervalDuration OID value, configure state conditions and alerts, and monitor any BATM Advanced Communications circuit emulation/pseudowire gateway (TDM-over-packet) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.738privateVendorOIDPRIV-VENDORDEF-MIB
1.3.6.1.4.1.738.1prvt_productsPRVT-SWITCH-MIB
1.3.6.1.4.1.738.1.5switchPRVT-SWITCH-MIB
Numeric OIDNameModule
1.3.6.1.4.1.738.1.5.200prvtPwVcPRVT-PW-TDM-MIB
1.3.6.1.4.1.738.1.5.200.2prvtPwVcTDMMIBPRVT-PW-TDM-MIB
1.3.6.1.4.1.738.1.5.200.2.1prvtPwVcTDMObjectsPRVT-PW-TDM-MIB
1.3.6.1.4.1.738.1.5.200.2.1.6prvtPwVcTDMPerfIntervalTablePRVT-PW-TDM-MIB
1.3.6.1.4.1.738.1.5.200.2.1.6.1prvtPwVcTDMPerfIntervalEntryPRVT-PW-TDM-MIB
1.3.6.1.4.1.738.1.5.200.2.1.6.1.3prvtPwVcTDMPerfIntervalDurationPRVT-PW-TDM-MIB