PRVT-PW-TDM-MIB :: prvtPwVcTDMPerfCurrentPktsOoseq

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsPRVT-PW-TDM-MIBprvtPwVcTDMPerfCurrentPktsOoseq

prvtPwVcTDMPerfCurrentPktsOoseq

Module: PRVT-PW-TDM-MIB

OID (symbolic): PRVT-PW-TDM-MIB::prvtPwVcTDMPerfCurrentPktsOoseq

OID (numeric): 1.3.6.1.4.1.738.1.5.200.2.1.5.1.1

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: Number of packets detected out of sequence (via TDM header sequence numbers), but successfully re-ordered. Note: some implementations may not support this Feature.

What is prvtPwVcTDMPerfCurrentPktsOoseq?

Counts packets that arrived out of sequence (by TDM header sequence number) but were successfully reordered, during the current 15-minute interval; not all hardware supports this feature. Admins watch this counter for signs of packet reordering happening in the transport network.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.738.1.5.200.2.1.5.1.1
snmpwalk -v2c -c public <target> PRVT-PW-TDM-MIB::prvtPwVcTDMPerfCurrentPktsOoseq

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.738.1.5.200.2.1.5.1.1.1
snmpget -v2c -c public <target> PRVT-PW-TDM-MIB::prvtPwVcTDMPerfCurrentPktsOoseq.1

Start monitoring BATM Advanced Communications circuit emulation/pseudowire gateway (TDM-over-packet) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the PRVT-PW-TDM-MIB::prvtPwVcTDMPerfCurrentPktsOoseq OID value, configure state conditions and alerts, and monitor any BATM Advanced Communications circuit emulation/pseudowire gateway (TDM-over-packet) from a single console.

How to Use in IPNetwork Monitor

Select a BATM Advanced Communications circuit emulation/pseudowire gateway (TDM-over-packet) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type prvtPwVcTDMPerfCurrentPktsOoseq into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. It reports the number of packets detected out of sequence (via TDM header sequence numbers), but successfully re-ordered. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.738privateVendorOIDPRIV-VENDORDEF-MIB
1.3.6.1.4.1.738.1prvt_productsPRVT-SWITCH-MIB
1.3.6.1.4.1.738.1.5switchPRVT-SWITCH-MIB
Numeric OIDNameModule
1.3.6.1.4.1.738.1.5.200prvtPwVcPRVT-PW-TDM-MIB
1.3.6.1.4.1.738.1.5.200.2prvtPwVcTDMMIBPRVT-PW-TDM-MIB
1.3.6.1.4.1.738.1.5.200.2.1prvtPwVcTDMObjectsPRVT-PW-TDM-MIB
1.3.6.1.4.1.738.1.5.200.2.1.5prvtPwVcTDMPerfCurrentTablePRVT-PW-TDM-MIB
1.3.6.1.4.1.738.1.5.200.2.1.5.1prvtPwVcTDMPerfCurrentEntryPRVT-PW-TDM-MIB
1.3.6.1.4.1.738.1.5.200.2.1.5.1.1prvtPwVcTDMPerfCurrentPktsOoseqPRVT-PW-TDM-MIB