PRVT-PW-TDM-MIB :: prvtPwVcTDMAlarmVariable

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsPRVT-PW-TDM-MIBprvtPwVcTDMAlarmVariable

prvtPwVcTDMAlarmVariable

Module: PRVT-PW-TDM-MIB

OID (symbolic): PRVT-PW-TDM-MIB::prvtPwVcTDMAlarmVariable

OID (numeric): 1.3.6.1.4.1.738.1.5.200.2.1.8.1.2

Node type: OBJECT-TYPE

Type: OBJECT IDENTIFIER

Access: read-only

Description: The OID of the variable whose value is being monitored. Depending on the time interval, the error condition and the modue and circuit ID, this points to an object from an entry in prvtPwVcTDMPerfCurrentTable or prvtPwVcTDMPerfTable.

What is prvtPwVcTDMAlarmVariable?

Holds the OID of the specific performance counter (from prvtPwVcTDMPerfCurrentTable or prvtPwVcTDMPerfTable) that this alarm entry is monitoring for a given module, circuit, and time interval. Admins read this to know exactly which underlying statistic triggered or will trigger the alarm.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.738.1.5.200.2.1.8.1.2
snmpwalk -v2c -c public <target> PRVT-PW-TDM-MIB::prvtPwVcTDMAlarmVariable

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.738.1.5.200.2.1.8.1.2.1
snmpget -v2c -c public <target> PRVT-PW-TDM-MIB::prvtPwVcTDMAlarmVariable.1

Start monitoring BATM Advanced Communications circuit emulation/pseudowire gateway (TDM-over-packet) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the PRVT-PW-TDM-MIB::prvtPwVcTDMAlarmVariable OID value, configure state conditions and alerts, and monitor any BATM Advanced Communications circuit emulation/pseudowire gateway (TDM-over-packet) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.738privateVendorOIDPRIV-VENDORDEF-MIB
1.3.6.1.4.1.738.1prvt_productsPRVT-SWITCH-MIB
1.3.6.1.4.1.738.1.5switchPRVT-SWITCH-MIB
Numeric OIDNameModule
1.3.6.1.4.1.738.1.5.200prvtPwVcPRVT-PW-TDM-MIB
1.3.6.1.4.1.738.1.5.200.2prvtPwVcTDMMIBPRVT-PW-TDM-MIB
1.3.6.1.4.1.738.1.5.200.2.1prvtPwVcTDMObjectsPRVT-PW-TDM-MIB
1.3.6.1.4.1.738.1.5.200.2.1.8prvtPwVcTDMAlarmTablePRVT-PW-TDM-MIB
1.3.6.1.4.1.738.1.5.200.2.1.8.1prvtPwVcTDMAlarmEntryPRVT-PW-TDM-MIB
1.3.6.1.4.1.738.1.5.200.2.1.8.1.2prvtPwVcTDMAlarmVariablePRVT-PW-TDM-MIB