All MIBs › PRIVAT-MultiLAN-Switch-MIB › hirmaBasBridgeMessage
hirmaBasBridgeMessage
Module: PRIVAT-MultiLAN-Switch-MIB
OID (symbolic): PRIVAT-MultiLAN-Switch-MIB::hirmaBasBridgeMessage
OID (numeric): 1.3.6.1.4.1.248.2.1.1.1.2.1.3
Node type: OBJECT-TYPE
Type: OCTET STRING
Access: read-only
Description: This object shows the message code according
to the following table.
1) error message
Code |Display| Description
***********************************************
0x45:0f | O | buffer overflow
0x45:91 | O | buffer overflow recovered
0x45:b3 | S | no carrier sense response
0x48:f6 | V | redundant power supply error
0x01:4f | A-a | shut-down TFTP transmission
0x81:a2 | A-b | TFTP transmission error
0x01:64 | A-t | TFTP transmission time out
0x01:65 | A-u | no TFTP server attached
| C-g | TCP communication problemes
| C-n | all TCP-devices are busy
| C-r | TCP rexmit timeout probleme
0x05:a5 | E-e | inaccessible transmission
0x05:88 | E-h | wrong LAN-controller state
0x05:ac | E-l | late collision detection
0x05:ad | E-m | too many collisions
0x05:b6 | E-u | internal transmission error
0x05:b8 | E-x | shut-down transmission
0x06:a1 | F-a | address table overflow
0x07:ce | F-b | inaccessible address table
0x06:a6 | F-f | type field table overflow
0x06:ad | F-m | rejected management packet (rx)
0x06:af | F-o | filter table overflow
0x06:b3 | F-s | filter table overflow
0x08:d7 | H-w | watchdog time out
0x09:89 | I-i | missing IP-address
0x09:8e | I-n | no response with RARP
| O-b | TCP buffer overflow
| O-f | no TCP connection
| O-k | TCP transmission error
| O-n | disabled TCP device
| S-c | wrong INI-file
2) fatal error messages
Code |Display| Errorcode
***********************************************
0x85:84 | E-d | LAN-controller test failed
0x85:87 | E-g | LAN-controller disabled
0x85:94 | E-t | LAN-controller error
0x88:8a | H-j | wrong master or malfunction
0x88:8d | H-m | no attached master
0x88:90 | H-p | processor test failed
0x8d:87 | M-g | global memory test failed
0x8d:8c | M-l | local memory test failed
0x8d:92 | M-r | ROM checksum test failedWhat is hirmaBasBridgeMessage?
Encodes a specific error or fatal-error code from the switch's internal fault table, covering conditions like buffer overflows, TFTP transfer failures, LAN-controller faults, and memory test failures. An admin looks up the returned code against the vendor's code table (e.g. hex 0x45:0f indicates a buffer overflow) to diagnose what triggered the logged event.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.248.2.1.1.1.2.1.3 snmpwalk -v2c -c public <target> PRIVAT-MultiLAN-Switch-MIB::hirmaBasBridgeMessage
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.248.2.1.1.1.2.1.3.1 snmpget -v2c -c public <target> PRIVAT-MultiLAN-Switch-MIB::hirmaBasBridgeMessage.1
Start monitoring Legacy Hirschmann MultiLAN Switch equipment with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the PRIVAT-MultiLAN-Switch-MIB::hirmaBasBridgeMessage OID value, configure state conditions and alerts, and monitor any Legacy Hirschmann MultiLAN Switch equipment from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.248 | hirschmann | HM2-TC-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.248.2 | multiLANSwitch | PRIVAT-MultiLAN-Switch-MIB |
| 1.3.6.1.4.1.248.2.1 | bridge1 | PRIVAT-MultiLAN-Switch-MIB |
| 1.3.6.1.4.1.248.2.1.1 | bridgemgmt | PRIVAT-MultiLAN-Switch-MIB |
| 1.3.6.1.4.1.248.2.1.1.1 | hirmaBasCapability | PRIVAT-MultiLAN-Switch-MIB |
| 1.3.6.1.4.1.248.2.1.1.1.2 | hirmaBasBridgeEventTable | PRIVAT-MultiLAN-Switch-MIB |
| 1.3.6.1.4.1.248.2.1.1.1.2.1 | hirmaBasBridgeEventEntry | PRIVAT-MultiLAN-Switch-MIB |
| 1.3.6.1.4.1.248.2.1.1.1.2.1.3 | hirmaBasBridgeMessage | PRIVAT-MultiLAN-Switch-MIB |