pktcMtaDevTimeServer

Module: PKTC-IETF-MTA-MIB

OID (symbolic): PKTC-IETF-MTA-MIB::pktcMtaDevTimeServer

OID (numeric): 1.3.6.1.2.1.140.1.2.8

Node type: OBJECT-TYPE

Type: InetAddress

Access: read-write

Description: This object contains the Internet Address of the Time Server used by an S-MTA for Time Synchronization. The type of this address is determined by the value of the pktcMtaDevTimeServerAddressType object. When the latter has the value 'ipv4(1)', this object contains the IP address of the Time Server used for Time Synchronization. In the case of an S-MTA, this object must be populated with a value other than 0.0.0.0 as obtained from DHCP option 4. The protocol by which the time of day MUST be retrieved is defined in RFC 868. In the case of an E-MTA, this object must contain a value of 0.0.0.0 if the address type is 'ipv4(1)' since an E-MTA does not use the Time Protocol for time synchronization (an E-MTA uses the time retrieved by the DOCSIS cable modem). The behavior of this object when the value of pktcMtaDevTimeServerAddressType is other than 'ipv4(1)' is not presently specified, but it may be specified in future versions of this MIB module. If a value is written into an instance of pktcMtaDevTimeServer, the agent MUST NOT retain the supplied value across MTA re-initializations or reboots.

What is pktcMtaDevTimeServer?

The IP address of the RFC 868 Time Protocol server a standalone MTA (S-MTA) uses to synchronize its clock; an embedded MTA (E-MTA) instead reports 0.0.0.0 here since it gets time from its cable modem.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.2.1.140.1.2.8
snmpwalk -v2c -c public <target> PKTC-IETF-MTA-MIB::pktcMtaDevTimeServer

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.2.1.140.1.2.8.1
snmpget -v2c -c public <target> PKTC-IETF-MTA-MIB::pktcMtaDevTimeServer.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.2.1.140.1.2.8.1 s <value>

Start monitoring vendor-neutral, standards-based MIB, RFC 4682 (PacketCable/IPCablecom MTA provisioning) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the PKTC-IETF-MTA-MIB::pktcMtaDevTimeServer OID value, configure state conditions and alerts, and monitor any vendor-neutral, standards-based MIB, RFC 4682 (PacketCable/IPCablecom MTA provisioning) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.2mgmtAXON-MIB
1.3.6.1.2.1mib_2AXON-MIB
Numeric OIDNameModule
1.3.6.1.2.1.140pktcIetfMtaMibPKTC-IETF-MTA-MIB
1.3.6.1.2.1.140.1pktcMtaMibObjectsPKTC-IETF-MTA-MIB
1.3.6.1.2.1.140.1.2pktcMtaDevServerPKTC-IETF-MTA-MIB
1.3.6.1.2.1.140.1.2.8pktcMtaDevTimeServerPKTC-IETF-MTA-MIB