All MIBs › PEA-EQUIPMENT-IPDSLAM › nonFatalSoftwareError
nonFatalSoftwareError
Module: PEA-EQUIPMENT-IPDSLAM
OID (symbolic): PEA-EQUIPMENT-IPDSLAM::nonFatalSoftwareError
OID (numeric): 1.3.6.1.4.1.193.72.300.1.2.0.5
Node type: NOTIFICATION-TYPE
Description: A non-fatal SW error has been detected on the device. This type of software error is normally not fatal for your system, It could be a configuration error or a minor problem in the software, so do not panic if this alarm is seen.
Corrective Actions: - Save the alarm information to a file, e.g. using a screenshot. It has to show all the trap parameters. - Give a brief explanation to how the error was provoked. If it can be provoked again, then it is important for the Ericsson support team to know how this is done. - Create a trouble report, which includes the log files, and send it to Ericsson support.
Deprecated from: EDA 1.1 R2A
Parameters 1: Managed object class IPDSLAM 2: Managed object ID [MAC] 3: Sequence number [Alarm sequence number] 4: Perceived severity Major 5: Event time [Timestamp is retrieved from a SNTP server] 6: Event type ProcessingErrorAlarm 7: Probable cause SoftwareError 8: Process name [Name of DMAPI task] 9: Process state [DMAPI task state] 10: File name [The file name from where the alarm was sent] 11: Line no [The line number in the specified file] 12: Error code [Additional error information] 13: Error data [Additional data related to the error - hex bytes]
Examples
Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):
snmptrap -v2c -c public <manager> '' PEA-EQUIPMENT-IPDSLAM::nonFatalSoftwareError snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.193.72.300.1.2.0.5
Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):
snmptrapd -f -Lo -c /dev/null authCommunity log public
Example snmptrapd log entry:
zoo11-linux.zoo [UDP: [192.168.30.111]:65202->[192.168.30.10]:162]: DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (410890418) 47 days, 13:21:44.18 SNMPv2-MIB::snmpTrapOID.0 = OID: PEA-EQUIPMENT-IPDSLAM::nonFatalSoftwareError
Start monitoring Ericsson (Torrent/Diax) IP DSLAM chassis, broadband DSL access multiplexer (equipment/control status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the PEA-EQUIPMENT-IPDSLAM::nonFatalSoftwareError OID value, configure state conditions and alerts, and monitor any Ericsson (Torrent/Diax) IP DSLAM chassis, broadband DSL access multiplexer (equipment/control status) from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.193 | ericsson | ANS-COMMON-MIB |
| 1.3.6.1.4.1.193.72 | diaxMIB | DXD-SMI |
| 1.3.6.1.4.1.193.72.300 | peaIpDslam | DIESEL-SMI |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.193.72.300.1 | peaEquipmentIpDslam | PEA-EQUIPMENT-IPDSLAM |
| 1.3.6.1.4.1.193.72.300.1.2 | peaEquipmentIpDslamTraps | PEA-EQUIPMENT-IPDSLAM |
| 1.3.6.1.4.1.193.72.300.1.2.0 | traps | PEA-EQUIPMENT-IPDSLAM |
| 1.3.6.1.4.1.193.72.300.1.2.0.5 | nonFatalSoftwareError | PEA-EQUIPMENT-IPDSLAM |