PEA-EQUIPMENT-IPDSLAM :: bothFansCeasing

MIB Reference — IPNetwork Monitor · Updated September 21, 2026

All MIBs › PEA-EQUIPMENT-IPDSLAM › bothFansCeasing

bothFansCeasing

Module: PEA-EQUIPMENT-IPDSLAM

OID (symbolic): PEA-EQUIPMENT-IPDSLAM::bothFansCeasing

OID (numeric): 1.3.6.1.4.1.193.72.300.1.2.0.17

Node type: NOTIFICATION-TYPE

Description: Indicates that at least one of the fans is working again. This means that the fan control cannot secure that the temperature is kept in the normal state in the worst-case scenario (e.g. high environmental temperature, high traffic).

Deprecated from: EDA 1.1 R2A

Parameters 1: Managed object class IPDSLAM 2: Managed object ID [MAC] 3: Sequence number [Alarm sequence number] 4: Perceived severity Ceasing 5: Event time [Timestamp is retrieved from a SNTP server] 6: Event type Equipment 7: Probable cause CoolingFanFailure 8: Fan green status [Failed, Working] 9: Fan red status [Failed, Working]

Examples

Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):

snmptrap -v2c -c public <manager> '' PEA-EQUIPMENT-IPDSLAM::bothFansCeasing
snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.193.72.300.1.2.0.17

Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):

snmptrapd -f -Lo -c /dev/null authCommunity log public

Example snmptrapd log entry:

zoo11-linux.zoo [UDP: [192.168.30.111]:58200->[192.168.30.10]:162]:
  DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (235562840) 27 days, 6:20:28.40
  SNMPv2-MIB::snmpTrapOID.0 = OID: PEA-EQUIPMENT-IPDSLAM::bothFansCeasing

SNMPv3 example:

snmptrap -v3 -l authPriv -u snmpv3user -a SHA -A "AuthPass1" -x AES -X "PrivPass1" <manager> '' PEA-EQUIPMENT-IPDSLAM::bothFansCeasing

Start monitoring Ericsson (Torrent/Diax) IP DSLAM chassis, broadband DSL access multiplexer (equipment/control status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the PEA-EQUIPMENT-IPDSLAM::bothFansCeasing OID value, configure state conditions and alerts, and monitor any Ericsson (Torrent/Diax) IP DSLAM chassis, broadband DSL access multiplexer (equipment/control status) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.193ericssonANS-COMMON-MIB
1.3.6.1.4.1.193.72diaxMIBDXD-SMI
1.3.6.1.4.1.193.72.300peaIpDslamDIESEL-SMI
Numeric OIDNameModule
1.3.6.1.4.1.193.72.300.1peaEquipmentIpDslamPEA-EQUIPMENT-IPDSLAM
1.3.6.1.4.1.193.72.300.1.2peaEquipmentIpDslamTrapsPEA-EQUIPMENT-IPDSLAM
1.3.6.1.4.1.193.72.300.1.2.0trapsPEA-EQUIPMENT-IPDSLAM
1.3.6.1.4.1.193.72.300.1.2.0.17bothFansCeasingPEA-EQUIPMENT-IPDSLAM