All MIBs › PEA-BRIDGE-IPDSLAM › pvcUpstreamIpAclId
pvcUpstreamIpAclId
Module: PEA-BRIDGE-IPDSLAM
OID (symbolic): PEA-BRIDGE-IPDSLAM::pvcUpstreamIpAclId
OID (numeric): 1.3.6.1.4.1.193.72.300.30.1.3.1.105
Node type: OBJECT-TYPE
Type: Unsigned32
Access: read-write
Description:
Setting this value to non-zero will specify the IP ACL to be used in the upstream direction. The value of zero means no IP ACL is used for this PVC. Default value will be zero
Valid from: EDA 2.2 SP2
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.193.72.300.30.1.3.1.105 snmpwalk -v2c -c public <target> PEA-BRIDGE-IPDSLAM::pvcUpstreamIpAclId
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.193.72.300.30.1.3.1.105.1 snmpget -v2c -c public <target> PEA-BRIDGE-IPDSLAM::pvcUpstreamIpAclId.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.193.72.300.30.1.3.1.105.1 i <value>
OID Breakdown
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | BIANCA-BRICK-PPP-MIB |
| 1.3.6 | dod | BIANCA-BRICK-PPP-MIB |
| 1.3.6.1 | internet | BIANCA-BRICK-PPP-MIB |
| 1.3.6.1.4 | private | BIANCA-BRICK-PPP-MIB |
| 1.3.6.1.4.1 | enterprises | ANIROOT-MIB |
| 1.3.6.1.4.1.193 | ericsson | ANS-COMMON-MIB |
| 1.3.6.1.4.1.193.72 | diaxMIB | DXD-SMI |
| 1.3.6.1.4.1.193.72.300 | peaIpDslam | DIESEL-SMI |
| 1.3.6.1.4.1.193.72.300.30 | peaBridgeIpDslam | PEA-BRIDGE-IPDSLAM |
| 1.3.6.1.4.1.193.72.300.30.1 | bridgeControl | PEA-BRIDGE-IPDSLAM |
| 1.3.6.1.4.1.193.72.300.30.1.3 | pvcTable | PEA-BRIDGE-IPDSLAM |
| 1.3.6.1.4.1.193.72.300.30.1.3.1 | pvcEntry | PEA-BRIDGE-IPDSLAM |
| 1.3.6.1.4.1.193.72.300.30.1.3.1.105 | pvcUpstreamIpAclId | PEA-BRIDGE-IPDSLAM |