PDN-CROSSCONNECT-MIB :: devSyncDataPortAssignRate

MIB Reference — IPNetwork Monitor · Updated September 21, 2026

All MIBs › PDN-CROSSCONNECT-MIB › devSyncDataPortAssignRate

devSyncDataPortAssignRate

Module: PDN-CROSSCONNECT-MIB

OID (symbolic): PDN-CROSSCONNECT-MIB::devSyncDataPortAssignRate

OID (numeric): 1.3.6.1.4.1.1795.2.24.2.6.7.2.1.2

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: The synchronous data port rate expressed in Kbps for both data ports of the synchronous data port-to-synchronous data port assignment represented by this entry. The actual rate for the ports is obtained by reading the value of ifSpeed from the Interfaces table of MIB II (RFC 1213). The possible data rates depend on the current base rate configured for the data ports of this assignment. For example, rate280or320(5) represents a rate of 280 Kbps or 320 Kbps for a base rate of 56 Kbps or 64 Kbps, respectively. WARNING: changing this object's value, causes the DS0 channels assigned to the data port based on the previous rate to be deallocated. NOTE: this variable cannot be used independently to alter the value of the rate associated with a particular data port.

What is devSyncDataPortAssignRate?

This read-write value sets the synchronous data port rate, chosen from a fixed set of Kbps values like rate56or64(1) through rate1344or1536(24), shared by both ports of a port-to-port assignment; the MIB warns that changing this deallocates the DS0 channels previously assigned to the port based on the old rate, and this object alone cannot be used to change a port's rate independently. Admins use it, as part of a single SET PDU alongside devSyncDataPortAssignIfIndex, to configure a matching backup-port rate before completing a synchronous-data-port-to-port assignment. An admin setting up port 1 as a manual backup for port 3 would include both this rate object and the target ifIndex in the same SNMP SET request so the assignment completes atomically at matching rates.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1795.2.24.2.6.7.2.1.2
snmpwalk -v2c -c public <target> PDN-CROSSCONNECT-MIB::devSyncDataPortAssignRate

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1795.2.24.2.6.7.2.1.2.1
snmpget -v2c -c public <target> PDN-CROSSCONNECT-MIB::devSyncDataPortAssignRate.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.1795.2.24.2.6.7.2.1.2.1 i <value>

Start monitoring Paradyne xDSL access multiplexers/DSU-CSU equipment (cross-connect fabric mapping) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the PDN-CROSSCONNECT-MIB::devSyncDataPortAssignRate OID value, configure state conditions and alerts, and monitor any Paradyne xDSL access multiplexers/DSU-CSU equipment (cross-connect fabric mapping) from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1795pdynPDN-HEADER-MIB
1.3.6.1.4.1.1795.2pdn_mgmtPDN-HEADER-MIB
1.3.6.1.4.1.1795.2.24paradynePDN-HEADER-MIB
1.3.6.1.4.1.1795.2.24.2pdn_commonPDN-HEADER-MIB
1.3.6.1.4.1.1795.2.24.2.6pdn_interfacesPDN-HEADER-MIB
1.3.6.1.4.1.1795.2.24.2.6.7crossConnectPDN-HEADER-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1795.2.24.2.6.7.2devSyncDataPortAssignTablePDN-CROSSCONNECT-MIB
1.3.6.1.4.1.1795.2.24.2.6.7.2.1devSyncDataPortAssignEntryPDN-CROSSCONNECT-MIB
1.3.6.1.4.1.1795.2.24.2.6.7.2.1.2devSyncDataPortAssignRatePDN-CROSSCONNECT-MIB