All MIBs › PDN-CROSSCONNECT-MIB › devSyncDataPortAssignIfIndex
devSyncDataPortAssignIfIndex
Module: PDN-CROSSCONNECT-MIB
OID (symbolic): PDN-CROSSCONNECT-MIB::devSyncDataPortAssignIfIndex
OID (numeric): 1.3.6.1.4.1.1795.2.24.2.6.7.2.1.3
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: An index value that uniquely identifies the interface to which this synchronous data port is assigned. The interface identified by a particular value of this index is the same interface as identified by the same value of an ifIndex object instance in the Interfaces table of MIB II (RFC 1213). If no interface is currently connected to this data port, then this value should be zero. The value used to set this object must be the ifIndex value of another synchronous data port interface only (i.e., synchronous data port to DS0 channel assignment is allowed only in the DS1 Fractional Table, devDs1FracTable).
What is devSyncDataPortAssignIfIndex?
This read-write value identifies the other synchronous data port interface this port is cross-connected to for backup purposes, using the same ifIndex convention as MIB-II; a value of zero means no port is currently connected, and the value must reference another synchronous data port interface rather than a DS0 channel (channel-level assignment belongs in the separate DS1 Fractional Table). Admins set it, together with devSyncDataPortAssignRate in the same SET PDU, to manually route data from a primary port to a backup port and vice versa. An admin routing port 1's traffic to a manually attached backup device on port 3 would set this object on port 1's entry to ifIndex 3, which the unit automatically mirrors by assigning port 3 back to port 1 as well.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1795.2.24.2.6.7.2.1.3 snmpwalk -v2c -c public <target> PDN-CROSSCONNECT-MIB::devSyncDataPortAssignIfIndex
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.1795.2.24.2.6.7.2.1.3.1 snmpget -v2c -c public <target> PDN-CROSSCONNECT-MIB::devSyncDataPortAssignIfIndex.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.1795.2.24.2.6.7.2.1.3.1 i <value>
Start monitoring Paradyne xDSL access multiplexers/DSU-CSU equipment (cross-connect fabric mapping) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the PDN-CROSSCONNECT-MIB::devSyncDataPortAssignIfIndex OID value, configure state conditions and alerts, and monitor any Paradyne xDSL access multiplexers/DSU-CSU equipment (cross-connect fabric mapping) from a single console.
OID Breakdown
Upper-level ancestors (12 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.1795 | pdyn | PDN-HEADER-MIB |
| 1.3.6.1.4.1.1795.2 | pdn_mgmt | PDN-HEADER-MIB |
| 1.3.6.1.4.1.1795.2.24 | paradyne | PDN-HEADER-MIB |
| 1.3.6.1.4.1.1795.2.24.2 | pdn_common | PDN-HEADER-MIB |
| 1.3.6.1.4.1.1795.2.24.2.6 | pdn_interfaces | PDN-HEADER-MIB |
| 1.3.6.1.4.1.1795.2.24.2.6.7 | crossConnect | PDN-HEADER-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.1795.2.24.2.6.7.2 | devSyncDataPortAssignTable | PDN-CROSSCONNECT-MIB |
| 1.3.6.1.4.1.1795.2.24.2.6.7.2.1 | devSyncDataPortAssignEntry | PDN-CROSSCONNECT-MIB |
| 1.3.6.1.4.1.1795.2.24.2.6.7.2.1.3 | devSyncDataPortAssignIfIndex | PDN-CROSSCONNECT-MIB |