All MIBs › PCUBE-SE-MIB › pchassisVoltageAlarm
pchassisVoltageAlarm
Module: PCUBE-SE-MIB
OID (symbolic): PCUBE-SE-MIB::pchassisVoltageAlarm
OID (numeric): 1.3.6.1.4.1.5655.4.1.2.5
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: The chassis internal voltage alarm status. If the alarm is 'on' it indicates that the voltage level of one or more HW units is not in the normal range.
What is pchassisVoltageAlarm?
Indicates whether internal chassis voltage levels are within the normal range (off) or out of range on one or more hardware units (on). An admin treats this as a hardware-health alarm pointing at a failing power component, distinct from the separate power-supply-presence alarm.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5655.4.1.2.5 snmpwalk -v2c -c public <target> PCUBE-SE-MIB::pchassisVoltageAlarm
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.5655.4.1.2.5.1 snmpget -v2c -c public <target> PCUBE-SE-MIB::pchassisVoltageAlarm.1
Start monitoring Cisco SCE2000/SE100 Service Control Engine platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the PCUBE-SE-MIB::pchassisVoltageAlarm OID value, configure state conditions and alerts, and monitor any Cisco SCE2000/SE100 Service Control Engine platforms from a single console.
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.5655 | pcube | PCUBE-SMI |
| 1.3.6.1.4.1.5655.4 | pcubeWorkgroup | PCUBE-SMI |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.5655.4.1 | pcubeSEObjs | PCUBE-SE-MIB |
| 1.3.6.1.4.1.5655.4.1.2 | pchassisGrp | PCUBE-SE-MIB |
| 1.3.6.1.4.1.5655.4.1.2.5 | pchassisVoltageAlarm | PCUBE-SE-MIB |