OCCAM-MLT-MIB :: mltTestResistanceRrg

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › OCCAM-MLT-MIB › mltTestResistanceRrg

mltTestResistanceRrg

Module: OCCAM-MLT-MIB

OID (symbolic): OCCAM-MLT-MIB::mltTestResistanceRrg

OID (numeric): 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.25

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: DC resistance measurements will be based on a 3 terminal circuit model. Rtr, Rtg and Rrg will be provided. User will have the option of specifying 3 resistance ranges: (1) low, (2) medium, (3) high. If not specified, auto mode will be used. Resistance measurements will not be available if fuse test fails or alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state only.

What is mltTestResistanceRrg?

Part of the full mlt suite, this read-only value in Ohms reports the DC resistance between ring and ground, completing the three-terminal resistance model alongside Rtr and Rtg used to find ground faults on the pair. It is intrusive and skipped if the fuse test failed or an alarm is present.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.25
snmpwalk -v2c -c public <target> OCCAM-MLT-MIB::mltTestResistanceRrg

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.25.1
snmpget -v2c -c public <target> OCCAM-MLT-MIB::mltTestResistanceRrg.1

Start monitoring Occam Networks broadband access equipment (metallic line testing) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the OCCAM-MLT-MIB::mltTestResistanceRrg OID value, configure state conditions and alerts, and monitor any Occam Networks broadband access equipment (metallic line testing) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.6066occamOCCAM-REG-MODULE
1.3.6.1.4.1.6066.2occamGenericOCCAM-REG-MODULE
1.3.6.1.4.1.6066.2.1occamGenericModulesOCCAM-REG-MODULE
1.3.6.1.4.1.6066.2.1.1occamGenericMonitorModulesOCCAM-REG-MODULE
Numeric OIDNameModule
1.3.6.1.4.1.6066.2.1.1.3occamMltMibOCCAM-MLT-MIB
1.3.6.1.4.1.6066.2.1.1.3.3mltTestResultsOCCAM-MLT-MIB
1.3.6.1.4.1.6066.2.1.1.3.3.2mltTestResultsTableOCCAM-MLT-MIB
1.3.6.1.4.1.6066.2.1.1.3.3.2.1mltTestResultsEntryOCCAM-MLT-MIB
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.25mltTestResistanceRrgOCCAM-MLT-MIB