OCCAM-MLT-MIB :: mltTestIdentifier

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › OCCAM-MLT-MIB › mltTestIdentifier

mltTestIdentifier

Module: OCCAM-MLT-MIB

OID (symbolic): OCCAM-MLT-MIB::mltTestIdentifier

OID (numeric): 1.3.6.1.4.1.6066.2.1.1.3.1.1

Node type: OBJECT-TYPE

Type: MltTestIdentifier

Access: read-write

Description: Selects the mlt test to be run. Setting this value starts a test.

This is a required parameter.

Approximate expected test durations are as follows:

statusSuite 1 second mltSuite 1 minute activeModeVoltages 3 seconds highImpedanceModeVoltages 9 seconds dcResistance 18 seconds capacitance 18 seconds loopDetect 9 seconds loopLength 9 seconds.

What is mltTestIdentifier?

This read-write value selects which metallic line test to run on the line, and writing to it immediately starts that test - options include a quick statusSuite (about 1 second), the full mltSuite (about 1 minute), or narrower tests like dcResistance or loopLength (9-18 seconds each). A technician troubleshooting a subscriber's DSL line would set this to loopLength to estimate cable distance to a fault. Because tests take seconds to over a minute, poll mltLastTestStatus or wait for the completion notification rather than re-reading immediately.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6066.2.1.1.3.1.1
snmpwalk -v2c -c public <target> OCCAM-MLT-MIB::mltTestIdentifier

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.6066.2.1.1.3.1.1.1
snmpget -v2c -c public <target> OCCAM-MLT-MIB::mltTestIdentifier.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.6066.2.1.1.3.1.1.1 s <value>

Start monitoring Occam Networks broadband access equipment (metallic line testing) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the OCCAM-MLT-MIB::mltTestIdentifier OID value, configure state conditions and alerts, and monitor any Occam Networks broadband access equipment (metallic line testing) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.6066occamOCCAM-REG-MODULE
1.3.6.1.4.1.6066.2occamGenericOCCAM-REG-MODULE
1.3.6.1.4.1.6066.2.1occamGenericModulesOCCAM-REG-MODULE
1.3.6.1.4.1.6066.2.1.1occamGenericMonitorModulesOCCAM-REG-MODULE
Numeric OIDNameModule
1.3.6.1.4.1.6066.2.1.1.3occamMltMibOCCAM-MLT-MIB
1.3.6.1.4.1.6066.2.1.1.3.1mltTestConfigOCCAM-MLT-MIB
1.3.6.1.4.1.6066.2.1.1.3.1.1mltTestIdentifierOCCAM-MLT-MIB