OCCAM-MLT-MIB :: mltTestGr909RingerTestRen

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › OCCAM-MLT-MIB › mltTestGr909RingerTestRen

mltTestGr909RingerTestRen

Module: OCCAM-MLT-MIB

OID (symbolic): OCCAM-MLT-MIB::mltTestGr909RingerTestRen

OID (numeric): 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.36

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: This test fails when the equivalent ringer count across tip and ring is less than 0.175 REN or greater than 5 REN. This test will not run if fuse test fails or alarm is present. This test will report passed/fail and the REN number. This parameter is intrusive and will be available in shutdown state shutdown only.

What is mltTestGr909RingerTestRen?

This read-only value, in units of 0.1 REN, reports the measured ringer equivalence number for the line as part of the GR-909 ringer test - a REN outside the 0.175 to 5 range is what drives mltTestGr909RingerTestResult to fail. An admin can use this to see whether too many phones are bridged onto one line.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.36
snmpwalk -v2c -c public <target> OCCAM-MLT-MIB::mltTestGr909RingerTestRen

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.36.1
snmpget -v2c -c public <target> OCCAM-MLT-MIB::mltTestGr909RingerTestRen.1

Start monitoring Occam Networks broadband access equipment (metallic line testing) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the OCCAM-MLT-MIB::mltTestGr909RingerTestRen OID value, configure state conditions and alerts, and monitor any Occam Networks broadband access equipment (metallic line testing) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.6066occamOCCAM-REG-MODULE
1.3.6.1.4.1.6066.2occamGenericOCCAM-REG-MODULE
1.3.6.1.4.1.6066.2.1occamGenericModulesOCCAM-REG-MODULE
1.3.6.1.4.1.6066.2.1.1occamGenericMonitorModulesOCCAM-REG-MODULE
Numeric OIDNameModule
1.3.6.1.4.1.6066.2.1.1.3occamMltMibOCCAM-MLT-MIB
1.3.6.1.4.1.6066.2.1.1.3.3mltTestResultsOCCAM-MLT-MIB
1.3.6.1.4.1.6066.2.1.1.3.3.2mltTestResultsTableOCCAM-MLT-MIB
1.3.6.1.4.1.6066.2.1.1.3.3.2.1mltTestResultsEntryOCCAM-MLT-MIB
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.36mltTestGr909RingerTestRenOCCAM-MLT-MIB