All MIBs › OCCAM-MLT-MIB › mltTestGr909RingerTestRen
mltTestGr909RingerTestRen
Module: OCCAM-MLT-MIB
OID (symbolic): OCCAM-MLT-MIB::mltTestGr909RingerTestRen
OID (numeric): 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.36
Node type: OBJECT-TYPE
Type: Integer32
Access: read-only
Description: This test fails when the equivalent ringer count across tip and ring is less than 0.175 REN or greater than 5 REN. This test will not run if fuse test fails or alarm is present. This test will report passed/fail and the REN number. This parameter is intrusive and will be available in shutdown state shutdown only.
What is mltTestGr909RingerTestRen?
This read-only value, in units of 0.1 REN, reports the measured ringer equivalence number for the line as part of the GR-909 ringer test - a REN outside the 0.175 to 5 range is what drives mltTestGr909RingerTestResult to fail. An admin can use this to see whether too many phones are bridged onto one line.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.36 snmpwalk -v2c -c public <target> OCCAM-MLT-MIB::mltTestGr909RingerTestRen
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.36.1 snmpget -v2c -c public <target> OCCAM-MLT-MIB::mltTestGr909RingerTestRen.1
Start monitoring Occam Networks broadband access equipment (metallic line testing) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the OCCAM-MLT-MIB::mltTestGr909RingerTestRen OID value, configure state conditions and alerts, and monitor any Occam Networks broadband access equipment (metallic line testing) from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.6066 | occam | OCCAM-REG-MODULE |
| 1.3.6.1.4.1.6066.2 | occamGeneric | OCCAM-REG-MODULE |
| 1.3.6.1.4.1.6066.2.1 | occamGenericModules | OCCAM-REG-MODULE |
| 1.3.6.1.4.1.6066.2.1.1 | occamGenericMonitorModules | OCCAM-REG-MODULE |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.6066.2.1.1.3 | occamMltMib | OCCAM-MLT-MIB |
| 1.3.6.1.4.1.6066.2.1.1.3.3 | mltTestResults | OCCAM-MLT-MIB |
| 1.3.6.1.4.1.6066.2.1.1.3.3.2 | mltTestResultsTable | OCCAM-MLT-MIB |
| 1.3.6.1.4.1.6066.2.1.1.3.3.2.1 | mltTestResultsEntry | OCCAM-MLT-MIB |
| 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.36 | mltTestGr909RingerTestRen | OCCAM-MLT-MIB |