All MIBs › OCCAM-MLT-MIB › mltTestGr909HazardousPotentialTestResult
mltTestGr909HazardousPotentialTestResult
Module: OCCAM-MLT-MIB
OID (symbolic): OCCAM-MLT-MIB::mltTestGr909HazardousPotentialTestResult
OID (numeric): 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.26
Node type: OBJECT-TYPE
Type: MltTestPassFail
Access: read-only
Description: This test fails if the T-G or R-G ac voltage is greater than 50 volts rms or the T-G or R-G dc voltage is greater than 135 volts. This test will report pass/fail. This test is intrusive and will be available in shutdown state only.
What is mltTestGr909HazardousPotentialTestResult?
This read-only pass/fail result from the full mlt suite reports the GR-909 hazardous potential test, which fails if the tip-ground or ring-ground AC voltage exceeds 50 Vrms or the DC voltage exceeds 135 V - conditions that could be unsafe for a technician working the line. A fail here should be treated as a safety flag before anyone touches the pair.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.26 snmpwalk -v2c -c public <target> OCCAM-MLT-MIB::mltTestGr909HazardousPotentialTestResult
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.26.1 snmpget -v2c -c public <target> OCCAM-MLT-MIB::mltTestGr909HazardousPotentialTestResult.1
Start monitoring Occam Networks broadband access equipment (metallic line testing) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the OCCAM-MLT-MIB::mltTestGr909HazardousPotentialTestResult OID value, configure state conditions and alerts, and monitor any Occam Networks broadband access equipment (metallic line testing) from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.6066 | occam | OCCAM-REG-MODULE |
| 1.3.6.1.4.1.6066.2 | occamGeneric | OCCAM-REG-MODULE |
| 1.3.6.1.4.1.6066.2.1 | occamGenericModules | OCCAM-REG-MODULE |
| 1.3.6.1.4.1.6066.2.1.1 | occamGenericMonitorModules | OCCAM-REG-MODULE |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.6066.2.1.1.3 | occamMltMib | OCCAM-MLT-MIB |
| 1.3.6.1.4.1.6066.2.1.1.3.3 | mltTestResults | OCCAM-MLT-MIB |
| 1.3.6.1.4.1.6066.2.1.1.3.3.2 | mltTestResultsTable | OCCAM-MLT-MIB |
| 1.3.6.1.4.1.6066.2.1.1.3.3.2.1 | mltTestResultsEntry | OCCAM-MLT-MIB |
| 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.26 | mltTestGr909HazardousPotentialTestResult | OCCAM-MLT-MIB |