OCCAM-MLT-MIB :: mltTestGr909HazardousPotentialTestResult

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › OCCAM-MLT-MIB › mltTestGr909HazardousPotentialTestResult

mltTestGr909HazardousPotentialTestResult

Module: OCCAM-MLT-MIB

OID (symbolic): OCCAM-MLT-MIB::mltTestGr909HazardousPotentialTestResult

OID (numeric): 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.26

Node type: OBJECT-TYPE

Type: MltTestPassFail

Access: read-only

Description: This test fails if the T-G or R-G ac voltage is greater than 50 volts rms or the T-G or R-G dc voltage is greater than 135 volts. This test will report pass/fail. This test is intrusive and will be available in shutdown state only.

What is mltTestGr909HazardousPotentialTestResult?

This read-only pass/fail result from the full mlt suite reports the GR-909 hazardous potential test, which fails if the tip-ground or ring-ground AC voltage exceeds 50 Vrms or the DC voltage exceeds 135 V - conditions that could be unsafe for a technician working the line. A fail here should be treated as a safety flag before anyone touches the pair.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.26
snmpwalk -v2c -c public <target> OCCAM-MLT-MIB::mltTestGr909HazardousPotentialTestResult

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.26.1
snmpget -v2c -c public <target> OCCAM-MLT-MIB::mltTestGr909HazardousPotentialTestResult.1

Start monitoring Occam Networks broadband access equipment (metallic line testing) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the OCCAM-MLT-MIB::mltTestGr909HazardousPotentialTestResult OID value, configure state conditions and alerts, and monitor any Occam Networks broadband access equipment (metallic line testing) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.6066occamOCCAM-REG-MODULE
1.3.6.1.4.1.6066.2occamGenericOCCAM-REG-MODULE
1.3.6.1.4.1.6066.2.1occamGenericModulesOCCAM-REG-MODULE
1.3.6.1.4.1.6066.2.1.1occamGenericMonitorModulesOCCAM-REG-MODULE
Numeric OIDNameModule
1.3.6.1.4.1.6066.2.1.1.3occamMltMibOCCAM-MLT-MIB
1.3.6.1.4.1.6066.2.1.1.3.3mltTestResultsOCCAM-MLT-MIB
1.3.6.1.4.1.6066.2.1.1.3.3.2mltTestResultsTableOCCAM-MLT-MIB
1.3.6.1.4.1.6066.2.1.1.3.3.2.1mltTestResultsEntryOCCAM-MLT-MIB
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.26mltTestGr909HazardousPotentialTestResultOCCAM-MLT-MIB