OCCAM-MLT-MIB :: mltTestDcCurrentsIring

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › OCCAM-MLT-MIB › mltTestDcCurrentsIring

mltTestDcCurrentsIring

Module: OCCAM-MLT-MIB

OID (symbolic): OCCAM-MLT-MIB::mltTestDcCurrentsIring

OID (numeric): 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.19

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: Four DC currents will be reported: IT, IL, It and Ir. In normal condition, currents will be measured in active mode. These measurements will not be available if alarm is present.

What is mltTestDcCurrentsIring?

Part of the full mlt suite, this read-only value in 0.1 mA reports the DC current flowing on the ring conductor while measured in active mode, completing the four-current picture (IT, IL, It, Ir) used to characterize the loop. It is unavailable if an alarm was present during the test.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.19
snmpwalk -v2c -c public <target> OCCAM-MLT-MIB::mltTestDcCurrentsIring

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.19.1
snmpget -v2c -c public <target> OCCAM-MLT-MIB::mltTestDcCurrentsIring.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> mltTestDcCurrentsIring.1

Start monitoring Occam Networks broadband access equipment (metallic line testing) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the OCCAM-MLT-MIB::mltTestDcCurrentsIring OID value, configure state conditions and alerts, and monitor any Occam Networks broadband access equipment (metallic line testing) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.6066occamOCCAM-REG-MODULE
1.3.6.1.4.1.6066.2occamGenericOCCAM-REG-MODULE
1.3.6.1.4.1.6066.2.1occamGenericModulesOCCAM-REG-MODULE
1.3.6.1.4.1.6066.2.1.1occamGenericMonitorModulesOCCAM-REG-MODULE
Numeric OIDNameModule
1.3.6.1.4.1.6066.2.1.1.3occamMltMibOCCAM-MLT-MIB
1.3.6.1.4.1.6066.2.1.1.3.3mltTestResultsOCCAM-MLT-MIB
1.3.6.1.4.1.6066.2.1.1.3.3.2mltTestResultsTableOCCAM-MLT-MIB
1.3.6.1.4.1.6066.2.1.1.3.3.2.1mltTestResultsEntryOCCAM-MLT-MIB
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.19mltTestDcCurrentsIringOCCAM-MLT-MIB