OCCAM-MLT-MIB :: mltActiveModeVoltagesVactr

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › OCCAM-MLT-MIB › mltActiveModeVoltagesVactr

mltActiveModeVoltagesVactr

Module: OCCAM-MLT-MIB

OID (symbolic): OCCAM-MLT-MIB::mltActiveModeVoltagesVactr

OID (numeric): 1.3.6.1.4.1.6066.2.1.1.3.3.3.1.4

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. Thus, VT and VR measurements should be 0 volt. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only.

What is mltActiveModeVoltagesVactr?

From the standalone active-mode-voltages test, this read-only value in 0.1 Vrms reports the tip-ring AC voltage while the line is driven in active mode, which should read near 0 volts on a healthy pair. A raised value can indicate induced noise on the line.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6066.2.1.1.3.3.3.1.4
snmpwalk -v2c -c public <target> OCCAM-MLT-MIB::mltActiveModeVoltagesVactr

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.6066.2.1.1.3.3.3.1.4.1
snmpget -v2c -c public <target> OCCAM-MLT-MIB::mltActiveModeVoltagesVactr.1

Start monitoring Occam Networks broadband access equipment (metallic line testing) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the OCCAM-MLT-MIB::mltActiveModeVoltagesVactr OID value, configure state conditions and alerts, and monitor any Occam Networks broadband access equipment (metallic line testing) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.6066occamOCCAM-REG-MODULE
1.3.6.1.4.1.6066.2occamGenericOCCAM-REG-MODULE
1.3.6.1.4.1.6066.2.1occamGenericModulesOCCAM-REG-MODULE
1.3.6.1.4.1.6066.2.1.1occamGenericMonitorModulesOCCAM-REG-MODULE
Numeric OIDNameModule
1.3.6.1.4.1.6066.2.1.1.3occamMltMibOCCAM-MLT-MIB
1.3.6.1.4.1.6066.2.1.1.3.3mltTestResultsOCCAM-MLT-MIB
1.3.6.1.4.1.6066.2.1.1.3.3.3mltActiveModeVoltagesResultsTableOCCAM-MLT-MIB
1.3.6.1.4.1.6066.2.1.1.3.3.3.1mltActiveModeVoltagesResultsEntryOCCAM-MLT-MIB
1.3.6.1.4.1.6066.2.1.1.3.3.3.1.4mltActiveModeVoltagesVactrOCCAM-MLT-MIB