OCCAM-MLT-MIB :: mltActiveModeVoltagesVacrg

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › OCCAM-MLT-MIB › mltActiveModeVoltagesVacrg

mltActiveModeVoltagesVacrg

Module: OCCAM-MLT-MIB

OID (symbolic): OCCAM-MLT-MIB::mltActiveModeVoltagesVacrg

OID (numeric): 1.3.6.1.4.1.6066.2.1.1.3.3.3.1.6

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. Thus, VT and VR measurements should be 0 volt. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only.

What is mltActiveModeVoltagesVacrg?

From the standalone active-mode-voltages test, this read-only value in 0.1 Vrms reports the ring-ground AC voltage while the line is driven in active mode, rounding out the tip-ring and tip-ground AC readings for this test. It is only measured while the port is shut down for testing.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6066.2.1.1.3.3.3.1.6
snmpwalk -v2c -c public <target> OCCAM-MLT-MIB::mltActiveModeVoltagesVacrg

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.6066.2.1.1.3.3.3.1.6.1
snmpget -v2c -c public <target> OCCAM-MLT-MIB::mltActiveModeVoltagesVacrg.1

Start monitoring Occam Networks broadband access equipment (metallic line testing) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the OCCAM-MLT-MIB::mltActiveModeVoltagesVacrg OID value, configure state conditions and alerts, and monitor any Occam Networks broadband access equipment (metallic line testing) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.6066occamOCCAM-REG-MODULE
1.3.6.1.4.1.6066.2occamGenericOCCAM-REG-MODULE
1.3.6.1.4.1.6066.2.1occamGenericModulesOCCAM-REG-MODULE
1.3.6.1.4.1.6066.2.1.1occamGenericMonitorModulesOCCAM-REG-MODULE
Numeric OIDNameModule
1.3.6.1.4.1.6066.2.1.1.3occamMltMibOCCAM-MLT-MIB
1.3.6.1.4.1.6066.2.1.1.3.3mltTestResultsOCCAM-MLT-MIB
1.3.6.1.4.1.6066.2.1.1.3.3.3mltActiveModeVoltagesResultsTableOCCAM-MLT-MIB
1.3.6.1.4.1.6066.2.1.1.3.3.3.1mltActiveModeVoltagesResultsEntryOCCAM-MLT-MIB
1.3.6.1.4.1.6066.2.1.1.3.3.3.1.6mltActiveModeVoltagesVacrgOCCAM-MLT-MIB