All MIBs › Nortel-MsCarrier-MscPassport-UtpDpnTrunksMIB › mscDpnGateUtpFramerCriticalLinkUtilAlarmThreshold
mscDpnGateUtpFramerCriticalLinkUtilAlarmThreshold
Module: Nortel-MsCarrier-MscPassport-UtpDpnTrunksMIB
OID (symbolic): Nortel-MsCarrier-MscPassport-UtpDpnTrunksMIB::mscDpnGateUtpFramerCriticalLinkUtilAlarmThreshold
OID (numeric): 1.3.6.1.4.1.562.36.2.1.61.2.2.15.1.3
Node type: OBJECT-TYPE
Type: Unsigned32
Access: read-write
Description: This attribute provides the threshold value which defines when a critical alarm would be issued, denoting a sustained total average link utilization. The total average link utilization is calculated based on the number of received bytes. The Set alarm is issued after 3 minutes of utilization greater than the given threshold. The corresponding Clear alarm is issued after a subsequent 3 minutes of utilization less than or equal to the given threshold. The value 100% is used to disable an individual threshold. For values other than 100%, a semantic check ensures that the critical alarm threshold is greater than the other thresholds.
What is mscDpnGateUtpFramerCriticalLinkUtilAlarmThreshold?
This read-write value (0-100, default 95) sets the sustained total average link utilization percentage that triggers a critical alarm after 3 minutes above it, clearing after 3 minutes back at or below it; 100% disables this threshold, and it must stay above both the minor and major thresholds. Admins use this as the top-tier warning that a trunk is nearly saturated and needs urgent attention.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.61.2.2.15.1.3 snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-UtpDpnTrunksMIB::mscDpnGateUtpFramerCriticalLinkUtilAlarmThreshold
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.61.2.2.15.1.3.1 snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-UtpDpnTrunksMIB::mscDpnGateUtpFramerCriticalLinkUtilAlarmThreshold.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.562.36.2.1.61.2.2.15.1.3.1 i <value>
Start monitoring Nortel/Alcatel-Lucent Passport packet switch (UTP-based DPN trunk) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-UtpDpnTrunksMIB::mscDpnGateUtpFramerCriticalLinkUtilAlarmThreshold OID value, configure state conditions and alerts, and monitor any Nortel/Alcatel-Lucent Passport packet switch (UTP-based DPN trunk) from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.562 | nortel | Nortel-Magellan-Passport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36 | msCarrier | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2 | mscPassport | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2.1 | mscComponents | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2.1.61 | mscDpnGate | Nortel-MsCarrier-MscPassport-DpnTrunksMIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.562.36.2.1.61.2 | mscDpnGateUtp | Nortel-MsCarrier-MscPassport-UtpDpnTrunksMIB |
| 1.3.6.1.4.1.562.36.2.1.61.2.2 | mscDpnGateUtpFramer | Nortel-MsCarrier-MscPassport-UtpDpnTrunksMIB |
| 1.3.6.1.4.1.562.36.2.1.61.2.2.15 | mscDpnGateUtpFramerUtilThresholdTable | Nortel-MsCarrier-MscPassport-UtpDpnTrunksMIB |
| 1.3.6.1.4.1.562.36.2.1.61.2.2.15.1 | mscDpnGateUtpFramerUtilThresholdEntry | Nortel-MsCarrier-MscPassport-UtpDpnTrunksMIB |
| 1.3.6.1.4.1.562.36.2.1.61.2.2.15.1.3 | mscDpnGateUtpFramerCriticalLinkUtilAlarmThreshold | Nortel-MsCarrier-MscPassport-UtpDpnTrunksMIB |