All MIBs › Nortel-MsCarrier-MscPassport-UnackTrunksMIB › mscTrkUnAckedFramerCriticalLinkUtilAlarmThreshold
mscTrkUnAckedFramerCriticalLinkUtilAlarmThreshold
Module: Nortel-MsCarrier-MscPassport-UnackTrunksMIB
OID (symbolic): Nortel-MsCarrier-MscPassport-UnackTrunksMIB::mscTrkUnAckedFramerCriticalLinkUtilAlarmThreshold
OID (numeric): 1.3.6.1.4.1.562.36.2.1.60.2.2.15.1.3
Node type: OBJECT-TYPE
Type: Unsigned32
Access: read-write
Description: This attribute provides the threshold value which defines when a critical alarm would be issued, denoting a sustained total average link utilization. The total average link utilization is calculated based on the number of received bytes. The Set alarm is issued after 3 minutes of utilization greater than the given threshold. The corresponding Clear alarm is issued after a subsequent 3 minutes of utilization less than or equal to the given threshold. The value 100% is used to disable an individual threshold. For values other than 100%, a semantic check ensures that the critical alarm threshold is greater than the other thresholds.
What is mscTrkUnAckedFramerCriticalLinkUtilAlarmThreshold?
The link-utilization percentage (0-100, default 95) that triggers a critical alarm once sustained for 3 minutes, the highest of the three escalating utilization thresholds an admin can tune for this trunk.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.60.2.2.15.1.3 snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-UnackTrunksMIB::mscTrkUnAckedFramerCriticalLinkUtilAlarmThreshold
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.60.2.2.15.1.3.1 snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-UnackTrunksMIB::mscTrkUnAckedFramerCriticalLinkUtilAlarmThreshold.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.562.36.2.1.60.2.2.15.1.3.1 i <value>
Start monitoring Nortel/Bay Networks Passport switch (unacknowledged/best-effort trunks) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-UnackTrunksMIB::mscTrkUnAckedFramerCriticalLinkUtilAlarmThreshold OID value, configure state conditions and alerts, and monitor any Nortel/Bay Networks Passport switch (unacknowledged/best-effort trunks) from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.562 | nortel | CPM-NORTEL-MIB |
| 1.3.6.1.4.1.562.36 | msCarrier | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2 | mscPassport | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2.1 | mscComponents | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2.1.60 | mscTrk | Nortel-MsCarrier-MscPassport-TrunksMIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.562.36.2.1.60.2 | mscTrkUnAcked | Nortel-MsCarrier-MscPassport-UnackTrunksMIB |
| 1.3.6.1.4.1.562.36.2.1.60.2.2 | mscTrkUnAckedFramer | Nortel-MsCarrier-MscPassport-UnackTrunksMIB |
| 1.3.6.1.4.1.562.36.2.1.60.2.2.15 | mscTrkUnAckedFramerUtilThresholdTable | Nortel-MsCarrier-MscPassport-UnackTrunksMIB |
| 1.3.6.1.4.1.562.36.2.1.60.2.2.15.1 | mscTrkUnAckedFramerUtilThresholdEntry | Nortel-MsCarrier-MscPassport-UnackTrunksMIB |
| 1.3.6.1.4.1.562.36.2.1.60.2.2.15.1.3 | mscTrkUnAckedFramerCriticalLinkUtilAlarmThreshold | Nortel-MsCarrier-MscPassport-UnackTrunksMIB |