Nortel-MsCarrier-MscPassport-UnackTrunksMIB DEFINITIONS ::= BEGIN IMPORTS OBJECT-TYPE FROM RFC-1212 mscPassportMIBs FROM Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB Counter32, DisplayString, StorageType, RowStatus, Gauge32, Unsigned32 FROM Nortel-MsCarrier-MscPassport-StandardTextualConventionsMIB NonReplicated, PassportCounter64, Link FROM Nortel-MsCarrier-MscPassport-TextualConventionsMIB mscTrk, mscTrkIndex FROM Nortel-MsCarrier-MscPassport-TrunksMIB; -- LAST-UPDATED "0011300000Z" -- ORGANIZATION "Nortel Networks" -- CONTACT-INFO " -- Nortel Carrier Data Network Management -- -- Postal: P.O. Box 3511, Station C -- Ottawa, Ontario -- Canada K1Y 4H7 -- -- via the WEB: http://www.nortelnetworks.com -- select 'Contact Us' from the menu -- -- via phone: 1-800-4NORTEL" -- DESCRIPTION -- "The module describing the Nortel MsCarrier MscPassport -- UnackTrunks Enterprise MIB." unackTrunksMIB OBJECT IDENTIFIER ::= { mscPassportMIBs 22 } -- Trunk/n Unacknowledged -- The Unacknowledged component provides a Layer 2 protocol that -- adds the minimum of overhead to data on the link. A Framer -- subcomponent is automatically added providing the underlying -- HDLC framing and associated hardware that the Unacknowledged -- component will use. mscTrkUnAcked OBJECT IDENTIFIER ::= { mscTrk 2 } mscTrkUnAckedRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF MscTrkUnAckedRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry controls the addition and deletion of mscTrkUnAcked components." ::= { mscTrkUnAcked 1 } mscTrkUnAckedRowStatusEntry OBJECT-TYPE SYNTAX MscTrkUnAckedRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single mscTrkUnAcked component." INDEX { mscTrkIndex, mscTrkUnAckedIndex } ::= { mscTrkUnAckedRowStatusTable 1 } MscTrkUnAckedRowStatusEntry ::= SEQUENCE { mscTrkUnAckedRowStatus RowStatus, mscTrkUnAckedComponentName DisplayString, mscTrkUnAckedStorageType StorageType, mscTrkUnAckedIndex NonReplicated } mscTrkUnAckedRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of mscTrkUnAcked components. These components can be added and deleted." ::= { mscTrkUnAckedRowStatusEntry 1 } mscTrkUnAckedComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { mscTrkUnAckedRowStatusEntry 2 } mscTrkUnAckedStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the mscTrkUnAcked tables." ::= { mscTrkUnAckedRowStatusEntry 4 } mscTrkUnAckedIndex OBJECT-TYPE SYNTAX NonReplicated ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the index for the mscTrkUnAcked tables." ::= { mscTrkUnAckedRowStatusEntry 10 } mscTrkUnAckedProvTable OBJECT-TYPE SYNTAX SEQUENCE OF MscTrkUnAckedProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group of provisionable attributes contains the parameters used by Unacknowledged, Utp, and FrAccess for monitoring link quality." ::= { mscTrkUnAcked 10 } mscTrkUnAckedProvEntry OBJECT-TYPE SYNTAX MscTrkUnAckedProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscTrkUnAckedProvTable." INDEX { mscTrkIndex, mscTrkUnAckedIndex } ::= { mscTrkUnAckedProvTable 1 } MscTrkUnAckedProvEntry ::= SEQUENCE { mscTrkUnAckedMaximumErroredInterval Unsigned32, mscTrkUnAckedReceiveErrorSensitivity Unsigned32 } mscTrkUnAckedMaximumErroredInterval OBJECT-TYPE SYNTAX Unsigned32 (0 | 1..15) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the interval time over which the error threshold (as specified by receiveErrorSensitivity) must be continuously exceeded before the Unacknowledged, Utp, or FrAccess component can be degraded. Once the error interval count exceeds the provisioned value, the Unacknowledged, Utp, or FrAccess component issues an alarm indicating that link quality has degraded, and it disables its parent component. The exception to this is a value of zero, the default, which indicates that the mechanism is completely disabled." DEFVAL { 0 } ::= { mscTrkUnAckedProvEntry 1 } mscTrkUnAckedReceiveErrorSensitivity OBJECT-TYPE SYNTAX Unsigned32 (0 | 1..10) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute is the allowable error rate beyond which the Unacknowledged, Utp, or FrAccess component can be degraded if it persists for a duration longer than the maximumErrorInterval. The threshold is expressed as a percentage of number of errored frames in the last interval per number of frames received in the last interval. The exception to this is a value of zero, which indicates that the mechanism is completely disabled. The configurable values are: 0 = the mechanism is completely disabled 1 = 1/(2**1) 2 = 1/(2**2) 3 = 1/(2**3) : 10 = 1/(2**10)" DEFVAL { 3 } ::= { mscTrkUnAckedProvEntry 2 } mscTrkUnAckedStateTable OBJECT-TYPE SYNTAX SEQUENCE OF MscTrkUnAckedStateEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group contains the three OSI State attributes and the six OSI Status attributes. The descriptions generically indicate what each attribute implies about the component. Note that not all the values and state combinations described here are supported by every component which reuses this group. For component-specific information and the valid state combinations, refer to the appropriate NTP." ::= { mscTrkUnAcked 11 } mscTrkUnAckedStateEntry OBJECT-TYPE SYNTAX MscTrkUnAckedStateEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscTrkUnAckedStateTable." INDEX { mscTrkIndex, mscTrkUnAckedIndex } ::= { mscTrkUnAckedStateTable 1 } MscTrkUnAckedStateEntry ::= SEQUENCE { mscTrkUnAckedAdminState INTEGER, mscTrkUnAckedOperationalState INTEGER, mscTrkUnAckedUsageState INTEGER, mscTrkUnAckedAvailabilityStatus OCTET STRING, mscTrkUnAckedProceduralStatus OCTET STRING, mscTrkUnAckedControlStatus OCTET STRING, mscTrkUnAckedAlarmStatus OCTET STRING, mscTrkUnAckedStandbyStatus INTEGER, mscTrkUnAckedUnknownStatus INTEGER } mscTrkUnAckedAdminState OBJECT-TYPE SYNTAX INTEGER { locked(0), unlocked(1), shuttingDown(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the OSI Administrative State of the component. The value locked indicates that the component is administratively prohibited from providing services for its users. A Lock -force or Lock command has been previously issued for this component. When the value is locked, the value of usageState must be idle. The value shuttingDown indicates that the component is administratively permitted to provide service to its existing users only. A Lock command was issued against the component and it is in the process of shutting down. The value unlocked indicates that the component is administratively permitted to provide services for its users. To enter this state, issue an Unlock command to this component. The OSI Status attributes, if supported by the component, may provide more details, qualifying the state of the component." DEFVAL { unlocked } ::= { mscTrkUnAckedStateEntry 1 } mscTrkUnAckedOperationalState OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the OSI Operational State of the component. The value enabled indicates that the component is available for operation. Note that if adminState is locked, it would still not be providing service. The value disabled indicates that the component is not available for operation. For example, something is wrong with the component itself, or with another component on which this one depends. If the value is disabled, the usageState must be idle. The OSI Status attributes, if supported by the component, may provide more details, qualifying the state of the component." DEFVAL { disabled } ::= { mscTrkUnAckedStateEntry 2 } mscTrkUnAckedUsageState OBJECT-TYPE SYNTAX INTEGER { idle(0), active(1), busy(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the OSI Usage State of the component. The value idle indicates that the component is not currently in use. The value active indicates that the component is in use and has spare capacity to provide for additional users. The value busy indicates that the component is in use and has no spare operating capacity for additional users at this time. The OSI Status attributes, if supported by the component, may provide more details, qualifying the state of the component." DEFVAL { idle } ::= { mscTrkUnAckedStateEntry 3 } mscTrkUnAckedAvailabilityStatus OBJECT-TYPE SYNTAX OCTET STRING (SIZE (2)) ACCESS read-only STATUS mandatory DESCRIPTION "If supported by the component, this attribute indicates the OSI Availability status of the component. Note that, even though it is defined as a multi-valued set, at most one value is shown to the user. When no values are in the set, this indicates that either the attribute is not supported or that none of the status conditions described below is present. The value inTest indicates that the resource is undergoing a test procedure. If adminState is locked or shuttingDown, the normal users are precluded from using the resource and controlStatus is reservedForTest. Tests that do not exclude additional users can be present in any operational or administrative state but the reservedForTest condition should not be present. The value failed indicates that the component has an internal fault that prevents it from operating. The operationalState is disabled. The value dependency indicates that the component cannot operate because some other resource on which it depends is unavailable. The operationalState is disabled. The value powerOff indicates the resource requires power to be applied and it is not powered on. The operationalState is disabled. The value offLine indicates the resource requires a routine operation (either manual, automatic, or both) to be performed to place it on-line and make it available for use. The operationalState is disabled. The value offDuty indicates the resource is inactive in accordance with a predetermined time schedule. In the absence of other disabling conditions, the operationalState is enabled or disabled. The value degraded indicates the service provided by the component is degraded in some way, such as in speed or operating capacity. Usually, the resource remains available for service. The operationalState is almost always enabled. There is one exception where an operationalState of disabled is used in conjunction with degraded for a component which represents a rolled up view of a set of other components. The value notInstalled indicates the resource is not present. The operationalState is disabled. The value logFull is not used. The value migrating indicates that a software migration activation is in progress, making the component unavailable for other activities until the migration is complete. Description of bits: inTest(0) failed(1) powerOff(2) offLine(3) offDuty(4) dependency(5) degraded(6) notInstalled(7) logFull(8) migrating(9)" ::= { mscTrkUnAckedStateEntry 4 } mscTrkUnAckedProceduralStatus OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1)) ACCESS read-only STATUS mandatory DESCRIPTION "If supported by the component, this attribute indicates the OSI Procedural status of the component. Note that, even though it is defined as a multi-valued set, at most one value is shown to the user. When no values are in the set, this indicates that either the attribute is not supported or that none of the status conditions described below is present. The value initializationRequired indicates (for a resource which doesn't initialize autonomously) that initialization is required before it can perform its normal functions, and this procedure has not been initiated. The operationalState is disabled. The value notInitialized indicates (for a resource which does initialize autonomously) that initialization is required before it can perform its normal functions, and this procedure has not been initiated. The operationalState may be enabled or disabled. The value initializing indicates that initialization has been initiated but is not yet complete. The operationalState may be enabled or disabled. The value reporting indicates the resource has completed some processing operation and is notifying the results. The operationalState is enabled. The value terminating indicates the component is in a termination phase. If the resource doesn't reinitialize autonomously, operationalState is disabled; otherwise it is enabled or disabled. Description of bits: initializationRequired(0) notInitialized(1) initializing(2) reporting(3) terminating(4)" ::= { mscTrkUnAckedStateEntry 5 } mscTrkUnAckedControlStatus OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1)) ACCESS read-only STATUS mandatory DESCRIPTION "If supported by the component, this attribute indicates the OSI Control status of the component. Note that, even though it is defined as a multi-valued set, at most one value is shown to the user. When no values are in the set, this indicates that either the attribute is not supported or that none of the status conditions described below is present. The value subjectToTest indicates the resource is available but tests may be conducted simultaneously at unpredictable times, which may cause it to exhibit unusual characteristics. The value partOfServicesLocked indicates that part of the service is restricted from users of a resource. The adminState is unlocked. The value reservedForTest indicates that the component is administratively unavailable because it is undergoing a test procedure. The adminState is locked. The value suspended indicates that the service has been administratively suspended. Description of bits: subjectToTest(0) partOfServicesLocked(1) reservedForTest(2) suspended(3)" ::= { mscTrkUnAckedStateEntry 6 } mscTrkUnAckedAlarmStatus OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1)) ACCESS read-only STATUS mandatory DESCRIPTION "If supported by the component, this attribute indicates the OSI Alarm status of the component. Note that, even though it is defined as a multi-valued set, at most one value is shown to the user. When no values are in the set, this indicates that either the attribute is not supported or that none of the status conditions described below is present. The value underRepair indicates the component is currently being repaired. The operationalState is enabled or disabled. The value critical indicates one or more critical alarms are outstanding against the component. Other, less severe, alarms may also be outstanding. The operationalState is enabled or disabled. The value major indicates one or more major alarms are outstanding against the component. Other, less severe, alarms may also be outstanding. The operationalState is enabled or disabled. The value minor indicates one or more minor alarms are outstanding against the component. Other, less severe, alarms may also be outstanding. The operationalState is enabled or disabled. The value alarmOutstanding generically indicates that an alarm of some severity is outstanding against the component. Description of bits: underRepair(0) critical(1) major(2) minor(3) alarmOutstanding(4)" ::= { mscTrkUnAckedStateEntry 7 } mscTrkUnAckedStandbyStatus OBJECT-TYPE SYNTAX INTEGER { hotStandby(0), coldStandby(1), providingService(2), notSet(15) } ACCESS read-only STATUS mandatory DESCRIPTION "If supported by the component, this attribute indicates the OSI Standby status of the component. The value notSet indicates that either the attribute is not supported or that none of the status conditions described below is present. Note that this is a non-standard value, used because the original specification indicated this attribute was set-valued and thus, did not provide a value to indicate that none of the other three are applicable. The value hotStandby indicates that the resource is not providing service but will be immediately able to take over the role of the resource to be backed up, without initialization activity, and containing the same information as the resource to be backed up. The value coldStandby indicates the resource is a backup for another resource but will not be immediately able to take over the role of the backed up resource and will require some initialization activity. The value providingService indicates that this component, as a backup resource, is currently backing up another resource." DEFVAL { notSet } ::= { mscTrkUnAckedStateEntry 8 } mscTrkUnAckedUnknownStatus OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the OSI Unknown status of the component. The value false indicates that all of the other OSI State and Status attribute values can be considered accurate. The value true indicates that the actual state of the component is not known for sure." DEFVAL { false } ::= { mscTrkUnAckedStateEntry 9 } -- -- Trunk/n Unack Framer -- -- The Framer component controls link layer framing for application -- components sending and receiving data on a link interface. It is also -- through Framer, that an application component is associated with a -- specific hardware link interface. -- -- The Framer component provides provisionable attributes related to -- datapath aspects of the hardware interface (such as crc and frame -- length) rather than interface specific attributes (such as modem -- leads and clocking) which are associated with specific hardware -- components (such as V35/n or DS1/n). The Framer component also -- provides a provisionable attribute which binds the application -- component to a specific hardware component. -- -- The Framer component contains operational attributes for link -- interface datapath statistics (such as frame counts and aborts). -- mscTrkUnAckedFramer OBJECT IDENTIFIER ::= { mscTrkUnAcked 2 } mscTrkUnAckedFramerRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF MscTrkUnAckedFramerRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry controls the addition and deletion of mscTrkUnAckedFramer components." ::= { mscTrkUnAckedFramer 1 } mscTrkUnAckedFramerRowStatusEntry OBJECT-TYPE SYNTAX MscTrkUnAckedFramerRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single mscTrkUnAckedFramer component." INDEX { mscTrkIndex, mscTrkUnAckedIndex, mscTrkUnAckedFramerIndex } ::= { mscTrkUnAckedFramerRowStatusTable 1 } MscTrkUnAckedFramerRowStatusEntry ::= SEQUENCE { mscTrkUnAckedFramerRowStatus RowStatus, mscTrkUnAckedFramerComponentName DisplayString, mscTrkUnAckedFramerStorageType StorageType, mscTrkUnAckedFramerIndex NonReplicated } mscTrkUnAckedFramerRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-only STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of mscTrkUnAckedFramer components. These components cannot be added nor deleted." ::= { mscTrkUnAckedFramerRowStatusEntry 1 } mscTrkUnAckedFramerComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { mscTrkUnAckedFramerRowStatusEntry 2 } mscTrkUnAckedFramerStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the mscTrkUnAckedFramer tables." ::= { mscTrkUnAckedFramerRowStatusEntry 4 } mscTrkUnAckedFramerIndex OBJECT-TYPE SYNTAX NonReplicated ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the index for the mscTrkUnAckedFramer tables." ::= { mscTrkUnAckedFramerRowStatusEntry 10 } mscTrkUnAckedFramerProvTable OBJECT-TYPE SYNTAX SEQUENCE OF MscTrkUnAckedFramerProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group contains the base provisioning data for the Framer component. Application or hardware interface specific provisioning data is contained in other provisionable Framer groups." ::= { mscTrkUnAckedFramer 10 } mscTrkUnAckedFramerProvEntry OBJECT-TYPE SYNTAX MscTrkUnAckedFramerProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscTrkUnAckedFramerProvTable." INDEX { mscTrkIndex, mscTrkUnAckedIndex, mscTrkUnAckedFramerIndex } ::= { mscTrkUnAckedFramerProvTable 1 } MscTrkUnAckedFramerProvEntry ::= SEQUENCE { mscTrkUnAckedFramerInterfaceName Link } mscTrkUnAckedFramerInterfaceName OBJECT-TYPE SYNTAX Link ACCESS read-write STATUS mandatory DESCRIPTION "This attribute contains a hardware component name. The attribute associates the application with a specific link. This defines the module processor on which Framer's parent component (as well as Framer itself) will run." ::= { mscTrkUnAckedFramerProvEntry 1 } mscTrkUnAckedFramerLinkTable OBJECT-TYPE SYNTAX SEQUENCE OF MscTrkUnAckedFramerLinkEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group contains attributes defining the framing of data on the link interface." ::= { mscTrkUnAckedFramer 11 } mscTrkUnAckedFramerLinkEntry OBJECT-TYPE SYNTAX MscTrkUnAckedFramerLinkEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscTrkUnAckedFramerLinkTable." INDEX { mscTrkIndex, mscTrkUnAckedIndex, mscTrkUnAckedFramerIndex } ::= { mscTrkUnAckedFramerLinkTable 1 } MscTrkUnAckedFramerLinkEntry ::= SEQUENCE { mscTrkUnAckedFramerFramingType INTEGER, mscTrkUnAckedFramerDataInversion INTEGER, mscTrkUnAckedFramerFrameCrcType INTEGER, mscTrkUnAckedFramerFlagsBetweenFrames Unsigned32 } mscTrkUnAckedFramerFramingType OBJECT-TYPE SYNTAX INTEGER { hdlc(0), interrupting(1) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the type of framing protocol that will be used for frames transmitted to the link interface and received from the link interface. If the value of this attribute is set to the default interrupting, then a Proprietary hdlc protocol is used which allows for voice cells to interrupt transmission of data frames, transmit the voice cell, and then continue transmitting the data frame. If the value of this attribute is set to hdlc, then the standard hdlc procotol is used for the sequential transmission of individual frames." DEFVAL { interrupting } ::= { mscTrkUnAckedFramerLinkEntry 1 } mscTrkUnAckedFramerDataInversion OBJECT-TYPE SYNTAX INTEGER { off(0), on(16) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute determines whether data bits are to be inverted (1 to 0 and 0 to 1) before transmission of frames to the interface. If the value of this attribute is On, the incoming data bits will also be inverted when frames are received from the link before being processed. This option is typically used in hdlc framing mode when inversion is used to guarantee 1's density. Note that aborts (in hdlc and interrupting modes) are corrupted when data is inverted." DEFVAL { off } ::= { mscTrkUnAckedFramerLinkEntry 2 } mscTrkUnAckedFramerFrameCrcType OBJECT-TYPE SYNTAX INTEGER { crc16(0), crc32(1), noCrc(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute defines the type of CRC used. The CRC value calculated is appended to the end of the frames transmitted to the link. The CRC value is removed from the end of frames received from the link and checked for correctness. NoCrc means that CRC is not used." DEFVAL { crc16 } ::= { mscTrkUnAckedFramerLinkEntry 3 } mscTrkUnAckedFramerFlagsBetweenFrames OBJECT-TYPE SYNTAX Unsigned32 (1..16) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute defines the number of flags that are inserted between frames sent to the link interface." DEFVAL { 1 } ::= { mscTrkUnAckedFramerLinkEntry 4 } mscTrkUnAckedFramerStateTable OBJECT-TYPE SYNTAX SEQUENCE OF MscTrkUnAckedFramerStateEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group contains the three OSI State attributes. The descriptions generically indicate what each state attribute implies about the component. Note that not all the values and state combinations described here are supported by every component which reuses this group. For component-specific information and the valid state combinations, refer to the appropriate NTP." ::= { mscTrkUnAckedFramer 12 } mscTrkUnAckedFramerStateEntry OBJECT-TYPE SYNTAX MscTrkUnAckedFramerStateEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscTrkUnAckedFramerStateTable." INDEX { mscTrkIndex, mscTrkUnAckedIndex, mscTrkUnAckedFramerIndex } ::= { mscTrkUnAckedFramerStateTable 1 } MscTrkUnAckedFramerStateEntry ::= SEQUENCE { mscTrkUnAckedFramerAdminState INTEGER, mscTrkUnAckedFramerOperationalState INTEGER, mscTrkUnAckedFramerUsageState INTEGER } mscTrkUnAckedFramerAdminState OBJECT-TYPE SYNTAX INTEGER { locked(0), unlocked(1), shuttingDown(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the OSI Administrative State of the component. The value locked indicates that the component is administratively prohibited from providing services for its users. A Lock -force or Lock command has been previously issued for this component. When the value is locked, the value of usageState must be idle. The value shuttingDown indicates that the component is administratively permitted to provide service to its existing users only. A Lock command was issued against the component and it is in the process of shutting down. The value unlocked indicates that the component is administratively permitted to provide services for its users. To enter this state, issue an Unlock command to this component." DEFVAL { unlocked } ::= { mscTrkUnAckedFramerStateEntry 1 } mscTrkUnAckedFramerOperationalState OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the OSI Operational State of the component. The value enabled indicates that the component is available for operation. Note that if adminState is locked, it would still not be providing service. The value disabled indicates that the component is not available for operation. For example, something is wrong with the component itself, or with another component on which this one depends. If the value is disabled, the usageState must be idle." DEFVAL { disabled } ::= { mscTrkUnAckedFramerStateEntry 2 } mscTrkUnAckedFramerUsageState OBJECT-TYPE SYNTAX INTEGER { idle(0), active(1), busy(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the OSI Usage State of the component. The value idle indicates that the component is not currently in use. The value active indicates that the component is in use and has spare capacity to provide for additional users. The value busy indicates that the component is in use and has no spare operating capacity for additional users at this time." DEFVAL { idle } ::= { mscTrkUnAckedFramerStateEntry 3 } mscTrkUnAckedFramerStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF MscTrkUnAckedFramerStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group contains the operational statistics data for a Unacknowledge Framer component." ::= { mscTrkUnAckedFramer 13 } mscTrkUnAckedFramerStatsEntry OBJECT-TYPE SYNTAX MscTrkUnAckedFramerStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscTrkUnAckedFramerStatsTable." INDEX { mscTrkIndex, mscTrkUnAckedIndex, mscTrkUnAckedFramerIndex } ::= { mscTrkUnAckedFramerStatsTable 1 } MscTrkUnAckedFramerStatsEntry ::= SEQUENCE { mscTrkUnAckedFramerFrmToIf Counter32, mscTrkUnAckedFramerFrmFromIf Counter32, mscTrkUnAckedFramerOctetFromIf Counter32, mscTrkUnAckedFramerAborts Counter32, mscTrkUnAckedFramerCrcErrors Counter32, mscTrkUnAckedFramerLrcErrors Counter32, mscTrkUnAckedFramerNonOctetErrors Counter32, mscTrkUnAckedFramerOverruns Counter32, mscTrkUnAckedFramerUnderruns Counter32, mscTrkUnAckedFramerLargeFrmErrors Counter32, mscTrkUnAckedFramerFrmModeErrors Counter32, mscTrkUnAckedFramerOutOfSequenceFrm Counter32, mscTrkUnAckedFramerRepeatedFrm Counter32, mscTrkUnAckedFramerFrmFromIf64 PassportCounter64, mscTrkUnAckedFramerOctetFromIf64 PassportCounter64 } mscTrkUnAckedFramerFrmToIf OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS obsolete DESCRIPTION "The number of frames transmitted to the link interface by Framer. Note: This does not include the number of frames transmitted directly to the hardware queue, thus bypassing the Framer component." ::= { mscTrkUnAckedFramerStatsEntry 1 } mscTrkUnAckedFramerFrmFromIf OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS obsolete DESCRIPTION "The number of frames received from the link interface by Framer." ::= { mscTrkUnAckedFramerStatsEntry 2 } mscTrkUnAckedFramerOctetFromIf OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS obsolete DESCRIPTION "The number of bytes received from the link interface by Framer." ::= { mscTrkUnAckedFramerStatsEntry 3 } mscTrkUnAckedFramerAborts OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute is the total number of aborts received." ::= { mscTrkUnAckedFramerStatsEntry 4 } mscTrkUnAckedFramerCrcErrors OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute is the total number of frames with with CRC errors." ::= { mscTrkUnAckedFramerStatsEntry 5 } mscTrkUnAckedFramerLrcErrors OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute is the total number of frames with LRC errors." ::= { mscTrkUnAckedFramerStatsEntry 6 } mscTrkUnAckedFramerNonOctetErrors OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute is the total number of frames that were non octet aligned." ::= { mscTrkUnAckedFramerStatsEntry 7 } mscTrkUnAckedFramerOverruns OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute is the total number of frames received from the link for which overruns occurred." ::= { mscTrkUnAckedFramerStatsEntry 8 } mscTrkUnAckedFramerUnderruns OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute is the total number of frames transmitted to the link for which underruns occurred." ::= { mscTrkUnAckedFramerStatsEntry 9 } mscTrkUnAckedFramerLargeFrmErrors OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute is the total number of frames received which were too large. The frame execeeded the maximumFrameLengthLimit provisioned attribute or it contained more than the 255 block hardware limit." ::= { mscTrkUnAckedFramerStatsEntry 10 } mscTrkUnAckedFramerFrmModeErrors OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute is the total number of frames detected with framing mode errors. A framingModeError is flagged when frames are inconsistent with the specified framingType, that is when interrupting frames are used while running in hdlc mode." ::= { mscTrkUnAckedFramerStatsEntry 11 } mscTrkUnAckedFramerOutOfSequenceFrm OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute is the total number of out of sequence frames in interrupting mode that have been received from the link." ::= { mscTrkUnAckedFramerStatsEntry 12 } mscTrkUnAckedFramerRepeatedFrm OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute is the total number of repeated frames (frames with the same sequence number) in interrupting mode that have been received from the link." ::= { mscTrkUnAckedFramerStatsEntry 13 } mscTrkUnAckedFramerFrmFromIf64 OBJECT-TYPE SYNTAX PassportCounter64 ACCESS read-only STATUS mandatory DESCRIPTION "The number of frames received from the link interface by Framer." ::= { mscTrkUnAckedFramerStatsEntry 15 } mscTrkUnAckedFramerOctetFromIf64 OBJECT-TYPE SYNTAX PassportCounter64 ACCESS read-only STATUS mandatory DESCRIPTION "The number of bytes received from the link interface by Framer." ::= { mscTrkUnAckedFramerStatsEntry 16 } mscTrkUnAckedFramerUtilTable OBJECT-TYPE SYNTAX SEQUENCE OF MscTrkUnAckedFramerUtilEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group contains the link utilization operational data for a Framer component." ::= { mscTrkUnAckedFramer 14 } mscTrkUnAckedFramerUtilEntry OBJECT-TYPE SYNTAX MscTrkUnAckedFramerUtilEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscTrkUnAckedFramerUtilTable." INDEX { mscTrkIndex, mscTrkUnAckedIndex, mscTrkUnAckedFramerIndex } ::= { mscTrkUnAckedFramerUtilTable 1 } MscTrkUnAckedFramerUtilEntry ::= SEQUENCE { mscTrkUnAckedFramerNormPrioLinkUtilToIf Gauge32, mscTrkUnAckedFramerHighPrioLinkUtilToIf Gauge32, mscTrkUnAckedFramerNormPrioLinkUtilFromIf Gauge32, mscTrkUnAckedFramerHighPrioLinkUtilFromIf Gauge32 } mscTrkUnAckedFramerNormPrioLinkUtilToIf OBJECT-TYPE SYNTAX Gauge32 (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute is the utilization of the normal and high priority data traffic (interruptable traffic) sent to the link as a percentage of the available bandwidth on the link. Note that this includes traffic with Transfer Priorities (TP) of 0, 6 and 9 and/or Emission Priority of 2 and 3. The utilization is the average for the last minute." DEFVAL { 0 } ::= { mscTrkUnAckedFramerUtilEntry 1 } mscTrkUnAckedFramerHighPrioLinkUtilToIf OBJECT-TYPE SYNTAX Gauge32 (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute is the utilization of the interrupting data traffic sent to the link as a percentage of the available bandwidth on the link. Note that this includes traffic with a Transfer Priority (TP) of 11 and/or Emission Priority of 1. The utilization is the average for the last minute." DEFVAL { 0 } ::= { mscTrkUnAckedFramerUtilEntry 2 } mscTrkUnAckedFramerNormPrioLinkUtilFromIf OBJECT-TYPE SYNTAX Gauge32 (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute is the utilization of the normal and high priority data traffic (interruptable traffic) received from the link as a percentage of the available bandwidth on the link. Note that this includes traffic with Transfer Priorities (TP) of 0, 6 and 9 and/or Emission Priority of 2 and 3. The utilization is the average for the last minute." DEFVAL { 0 } ::= { mscTrkUnAckedFramerUtilEntry 3 } mscTrkUnAckedFramerHighPrioLinkUtilFromIf OBJECT-TYPE SYNTAX Gauge32 (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute is the utilization of the interrupting data traffic received from the link as a percentage of the available bandwidth on the link. Note that this includes traffic with a Transfer Priority (TP) of 11 and/or Emission Priority of 1. The utilization is the average for the last minute." DEFVAL { 0 } ::= { mscTrkUnAckedFramerUtilEntry 4 } mscTrkUnAckedFramerUtilThresholdTable OBJECT-TYPE SYNTAX SEQUENCE OF MscTrkUnAckedFramerUtilThresholdEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group contains all of the provisioning data required to set the link utilization alarm thresholds. All thresholds are percentages which can take on any value in the range of 0% through 100%. The value 100% is used to disable an individual threshold. For values other than 100%, a semantic check ensures that the minor alarm threshold is less than the other thresholds and that the major alarm threshold is less than the critical alarm threshold." ::= { mscTrkUnAckedFramer 15 } mscTrkUnAckedFramerUtilThresholdEntry OBJECT-TYPE SYNTAX MscTrkUnAckedFramerUtilThresholdEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscTrkUnAckedFramerUtilThresholdTable." INDEX { mscTrkIndex, mscTrkUnAckedIndex, mscTrkUnAckedFramerIndex } ::= { mscTrkUnAckedFramerUtilThresholdTable 1 } MscTrkUnAckedFramerUtilThresholdEntry ::= SEQUENCE { mscTrkUnAckedFramerMinorLinkUtilAlarmThreshold Unsigned32, mscTrkUnAckedFramerMajorLinkUtilAlarmThreshold Unsigned32, mscTrkUnAckedFramerCriticalLinkUtilAlarmThreshold Unsigned32, mscTrkUnAckedFramerLinkUtilAlarmStatus INTEGER } mscTrkUnAckedFramerMinorLinkUtilAlarmThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..100) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute provides the threshold value which defines when a minor alarm would be issued, denoting a sustained total average link utilization. The total average link utilization is calculated based on the number of received bytes. The Set alarm is issued after 3 minutes of utilization greater than the given threshold. The corresponding Clear alarm is issued after a subsequent 3 minutes of utilization less than or equal to the given threshold. The value 100% is used to disable an individual threshold. For values other than 100%, a semantic check ensures that the minor alarm threshold is less than the other thresholds." DEFVAL { 75 } ::= { mscTrkUnAckedFramerUtilThresholdEntry 1 } mscTrkUnAckedFramerMajorLinkUtilAlarmThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..100) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute provides the threshold value which defines when a major alarm would be issued, denoting a sustained total average link utilization. The total average link utilization is calculated based on the number of received bytes. The Set alarm is issued after 3 minutes of utilization greater than the given threshold. The corresponding Clear alarm is issued after a subsequent 3 minutes of utilization less than or equal to the given threshold. The value 100% is used to disable an individual threshold. For values other than 100%, a semantic check ensures that the major alarm threshold is greater than the minor threshold and less than the critical threshold." DEFVAL { 85 } ::= { mscTrkUnAckedFramerUtilThresholdEntry 2 } mscTrkUnAckedFramerCriticalLinkUtilAlarmThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..100) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute provides the threshold value which defines when a critical alarm would be issued, denoting a sustained total average link utilization. The total average link utilization is calculated based on the number of received bytes. The Set alarm is issued after 3 minutes of utilization greater than the given threshold. The corresponding Clear alarm is issued after a subsequent 3 minutes of utilization less than or equal to the given threshold. The value 100% is used to disable an individual threshold. For values other than 100%, a semantic check ensures that the critical alarm threshold is greater than the other thresholds." DEFVAL { 95 } ::= { mscTrkUnAckedFramerUtilThresholdEntry 3 } mscTrkUnAckedFramerLinkUtilAlarmStatus OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute provides control of the generation of link utilization alarms. If the value is disabled, none of the alarms are generated (this is equivalent to setting all of the thresholds to 100%). If the value is enabled, the individual thresholds are handled." DEFVAL { disabled } ::= { mscTrkUnAckedFramerUtilThresholdEntry 4 } -- -- Version and Compliance statements -- -- Object-Group Statement: -- A list of all current accessible leaf objects. -- OBJECTS { mscTrkUnAckedMaximumErroredInterval, -- mscTrkUnAckedFramerLrcErrors, -- mscTrkUnAckedFramerMajorLinkUtilAlarmThreshold, -- mscTrkUnAckedControlStatus, -- mscTrkUnAckedAdminState, -- mscTrkUnAckedFramerFrmFromIf64, -- mscTrkUnAckedFramerRowStatus, -- mscTrkUnAckedFramerStorageType, -- mscTrkUnAckedFramerAborts, -- mscTrkUnAckedRowStatus, -- mscTrkUnAckedFramerOverruns, -- mscTrkUnAckedFramerLargeFrmErrors, -- mscTrkUnAckedFramerCrcErrors, -- mscTrkUnAckedProceduralStatus, -- mscTrkUnAckedFramerLinkUtilAlarmStatus, -- mscTrkUnAckedAvailabilityStatus, -- mscTrkUnAckedFramerNonOctetErrors, -- mscTrkUnAckedFramerOctetFromIf64, -- mscTrkUnAckedFramerCriticalLinkUtilAlarmThreshold, -- mscTrkUnAckedFramerUsageState, -- mscTrkUnAckedFramerOutOfSequenceFrm, -- mscTrkUnAckedFramerNormPrioLinkUtilFromIf, -- mscTrkUnAckedFramerRepeatedFrm, -- mscTrkUnAckedAlarmStatus, -- mscTrkUnAckedUsageState, -- mscTrkUnAckedFramerUnderruns, -- mscTrkUnAckedFramerInterfaceName, -- mscTrkUnAckedUnknownStatus, -- mscTrkUnAckedStandbyStatus, -- mscTrkUnAckedFramerComponentName, -- mscTrkUnAckedFramerFramingType, -- mscTrkUnAckedComponentName, -- mscTrkUnAckedFramerFlagsBetweenFrames, -- mscTrkUnAckedStorageType, -- mscTrkUnAckedFramerOperationalState, -- mscTrkUnAckedFramerDataInversion, -- mscTrkUnAckedFramerHighPrioLinkUtilFromIf, -- mscTrkUnAckedFramerHighPrioLinkUtilToIf, -- mscTrkUnAckedOperationalState, -- mscTrkUnAckedFramerFrmModeErrors, -- mscTrkUnAckedFramerMinorLinkUtilAlarmThreshold, -- mscTrkUnAckedFramerNormPrioLinkUtilToIf, -- mscTrkUnAckedReceiveErrorSensitivity, -- mscTrkUnAckedFramerFrameCrcType, -- mscTrkUnAckedFramerAdminState } -- STATUS mandatory -- DESCRIPTION -- "A list of all current accessible leaf objects." unackTrunksGroup OBJECT IDENTIFIER ::= { unackTrunksMIB 1 } unackTrunksGroupCB OBJECT IDENTIFIER ::= { unackTrunksGroup 2 } unackTrunksGroupCB01 OBJECT IDENTIFIER ::= { unackTrunksGroupCB 2 } unackTrunksGroupCB01A OBJECT IDENTIFIER ::= { unackTrunksGroupCB01 2 } -- Agent-Capabilities Statement: -- PRODUCT-RELEASE "MscPassport Release 2.2 UnackTrunks." -- STATUS mandatory -- DESCRIPTION "Carrier Passport UnackTrunks MIB: MIB Version CB01A, -- Software Version CB02S1B." -- SUPPORTS Nortel-MsCarrier-MscPassport-UnackTrunksMIB -- INCLUDES { unackTrunksGroupCB01A } unackTrunksCapabilities OBJECT IDENTIFIER ::= { unackTrunksMIB 3 } unackTrunksCapabilitiesCB OBJECT IDENTIFIER ::= { unackTrunksCapabilities 2 } unackTrunksCapabilitiesCB01 OBJECT IDENTIFIER ::= { unackTrunksCapabilitiesCB 2 } unackTrunksCapabilitiesCB01A OBJECT IDENTIFIER ::= { unackTrunksCapabilitiesCB01 2 } END