Nortel-MsCarrier-MscPassport-ServerAccessRsaMIB :: mscRsaDnaOutCalls

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › Nortel-MsCarrier-MscPassport-ServerAccessRsaMIB › mscRsaDnaOutCalls

mscRsaDnaOutCalls

Module: Nortel-MsCarrier-MscPassport-ServerAccessRsaMIB

OID (symbolic): Nortel-MsCarrier-MscPassport-ServerAccessRsaMIB::mscRsaDnaOutCalls

OID (numeric): 1.3.6.1.4.1.562.36.2.1.108.2.11.1.1

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: This attribute, if set to a value of allowed indicates that outgoing calls (from the DTE to the network) can be made using this particular Dna. If set to a value of disallowed, then outgoing calls cannot be made using this Dna - such calls will be cleared by the local DCE. This attribute corresponds to the ITU-T 'Outgoing Calls Barred' feature for Dnas in that outgoing calls are barred if this attribute is set to a value of disallowed. Either outCalls, or incCalls (or both) must be set to a value of allowed for this Dna to be usable.

What is mscRsaDnaOutCalls?

Controls whether outgoing calls (from the DTE into the network) may be placed using this Dna: allowed permits them, while disallowed causes such calls to be cleared by the local DCE (the ITU-T 'Outgoing Calls Barred' feature). At least one of this and mscRsaDnaIncCalls must be allowed for the Dna to be usable at all. Defaults to disallowed.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.108.2.11.1.1
snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-ServerAccessRsaMIB::mscRsaDnaOutCalls

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.108.2.11.1.1.1
snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-ServerAccessRsaMIB::mscRsaDnaOutCalls.1

Start monitoring Nortel MsCarrier/Magellan Passport switch (RSA SecurID admin access) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-ServerAccessRsaMIB::mscRsaDnaOutCalls OID value, configure state conditions and alerts, and monitor any Nortel MsCarrier/Magellan Passport switch (RSA SecurID admin access) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.562nortelCPM-NORTEL-MIB
1.3.6.1.4.1.562.36msCarrierNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2mscPassportNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2.1mscComponentsNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
Numeric OIDNameModule
1.3.6.1.4.1.562.36.2.1.108mscRsaNortel-MsCarrier-MscPassport-ServerAccessRsaMIB
1.3.6.1.4.1.562.36.2.1.108.2mscRsaDnaNortel-MsCarrier-MscPassport-ServerAccessRsaMIB
1.3.6.1.4.1.562.36.2.1.108.2.11mscRsaDnaOutgoingOptionsTableNortel-MsCarrier-MscPassport-ServerAccessRsaMIB
1.3.6.1.4.1.562.36.2.1.108.2.11.1mscRsaDnaOutgoingOptionsEntryNortel-MsCarrier-MscPassport-ServerAccessRsaMIB
1.3.6.1.4.1.562.36.2.1.108.2.11.1.1mscRsaDnaOutCallsNortel-MsCarrier-MscPassport-ServerAccessRsaMIB