Nortel-MsCarrier-MscPassport-ServerAccessRsaMIB :: mscRsaConnectionVcSegmentsSent

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › Nortel-MsCarrier-MscPassport-ServerAccessRsaMIB › mscRsaConnectionVcSegmentsSent

mscRsaConnectionVcSegmentsSent

Module: Nortel-MsCarrier-MscPassport-ServerAccessRsaMIB

OID (symbolic): Nortel-MsCarrier-MscPassport-ServerAccessRsaMIB::mscRsaConnectionVcSegmentsSent

OID (numeric): 1.3.6.1.4.1.562.36.2.1.108.4.2.11.1.4

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-only

Description: This attribute displays the number of segments sent at the time command was issued. This is the segment sent count maintained by accounting at the source Vc. Vc only counts packets that Vc thinks can be delivered successfully into the subnet. In reality, these packets may be dropped by trunking, for instance. This counter is not updated when splitting fails, when Vc is in a path recovery state, when packet forwarding fails to forward this packet and when subsequent packets have to be discarded as we want to minimize the chance of out-of-sequence and do not intentionally send out-of- sequenced packets into the subnet.

What is mscRsaConnectionVcSegmentsSent?

Reports how many segments this Vc has sent as of the time this was read; only counts segments the Vc believed could be delivered into the subnet -- it isn't updated when splitting fails, during path recovery, or when packet forwarding intentionally discards a segment to avoid sending out-of-sequence data.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.108.4.2.11.1.4
snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-ServerAccessRsaMIB::mscRsaConnectionVcSegmentsSent

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.108.4.2.11.1.4.1
snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-ServerAccessRsaMIB::mscRsaConnectionVcSegmentsSent.1

Start monitoring Nortel MsCarrier/Magellan Passport switch (RSA SecurID admin access) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-ServerAccessRsaMIB::mscRsaConnectionVcSegmentsSent OID value, configure state conditions and alerts, and monitor any Nortel MsCarrier/Magellan Passport switch (RSA SecurID admin access) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.562nortelCPM-NORTEL-MIB
1.3.6.1.4.1.562.36msCarrierNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2mscPassportNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2.1mscComponentsNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
Numeric OIDNameModule
1.3.6.1.4.1.562.36.2.1.108mscRsaNortel-MsCarrier-MscPassport-ServerAccessRsaMIB
1.3.6.1.4.1.562.36.2.1.108.4mscRsaConnectionNortel-MsCarrier-MscPassport-ServerAccessRsaMIB
1.3.6.1.4.1.562.36.2.1.108.4.2mscRsaConnectionVcNortel-MsCarrier-MscPassport-ServerAccessRsaMIB
1.3.6.1.4.1.562.36.2.1.108.4.2.11mscRsaConnectionVcIntdTableNortel-MsCarrier-MscPassport-ServerAccessRsaMIB
1.3.6.1.4.1.562.36.2.1.108.4.2.11.1mscRsaConnectionVcIntdEntryNortel-MsCarrier-MscPassport-ServerAccessRsaMIB
1.3.6.1.4.1.562.36.2.1.108.4.2.11.1.4mscRsaConnectionVcSegmentsSentNortel-MsCarrier-MscPassport-ServerAccessRsaMIB