mscRsaConnectionVcOoSeqByteCntExceeded
Module: Nortel-MsCarrier-MscPassport-ServerAccessRsaMIB
OID (symbolic): Nortel-MsCarrier-MscPassport-ServerAccessRsaMIB::mscRsaConnectionVcOoSeqByteCntExceeded
OID (numeric): 1.3.6.1.4.1.562.36.2.1.108.4.2.12.1.10
Node type: OBJECT-TYPE
Type: Unsigned32
Access: read-only
Description: This attribute displays the number times that the out of sequence byte threshold is exceeded. When the threshold is exceeded, this condition is treated as if the loss frame timer has expired and all frames queued at the sink Vc are delivered to the AP. We need to keep this count to examine if the threshold is engineered properly. This should be used in conjunction with the peak value of out-of- sequenced queue and the number of times the loss frame timer has expired. This count should be relatively small when compared with loss frame timer expiry count.
What is mscRsaConnectionVcOoSeqByteCntExceeded?
Counts how many times the out-of-sequence byte threshold was exceeded on this Vc, a condition handled the same as a lost-frame timer expiry (all queued frames are flushed to the AP); tracked to verify the threshold is engineered correctly, and expected to stay small relative to the actual loss-timer expiry count.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.108.4.2.12.1.10 snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-ServerAccessRsaMIB::mscRsaConnectionVcOoSeqByteCntExceeded
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.108.4.2.12.1.10.1 snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-ServerAccessRsaMIB::mscRsaConnectionVcOoSeqByteCntExceeded.1
Start monitoring Nortel MsCarrier/Magellan Passport switch (RSA SecurID admin access) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-ServerAccessRsaMIB::mscRsaConnectionVcOoSeqByteCntExceeded OID value, configure state conditions and alerts, and monitor any Nortel MsCarrier/Magellan Passport switch (RSA SecurID admin access) from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.562 | nortel | CPM-NORTEL-MIB |
| 1.3.6.1.4.1.562.36 | msCarrier | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2 | mscPassport | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2.1 | mscComponents | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.562.36.2.1.108 | mscRsa | Nortel-MsCarrier-MscPassport-ServerAccessRsaMIB |
| 1.3.6.1.4.1.562.36.2.1.108.4 | mscRsaConnection | Nortel-MsCarrier-MscPassport-ServerAccessRsaMIB |
| 1.3.6.1.4.1.562.36.2.1.108.4.2 | mscRsaConnectionVc | Nortel-MsCarrier-MscPassport-ServerAccessRsaMIB |
| 1.3.6.1.4.1.562.36.2.1.108.4.2.12 | mscRsaConnectionVcFrdTable | Nortel-MsCarrier-MscPassport-ServerAccessRsaMIB |
| 1.3.6.1.4.1.562.36.2.1.108.4.2.12.1 | mscRsaConnectionVcFrdEntry | Nortel-MsCarrier-MscPassport-ServerAccessRsaMIB |
| 1.3.6.1.4.1.562.36.2.1.108.4.2.12.1.10 | mscRsaConnectionVcOoSeqByteCntExceeded | Nortel-MsCarrier-MscPassport-ServerAccessRsaMIB |