mscRsaConnectionVcNotDataXferFromSubnet

Module: Nortel-MsCarrier-MscPassport-ServerAccessRsaMIB

OID (symbolic): Nortel-MsCarrier-MscPassport-ServerAccessRsaMIB::mscRsaConnectionVcNotDataXferFromSubnet

OID (numeric): 1.3.6.1.4.1.562.36.2.1.108.4.2.12.1.8

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-only

Description: This attribute displays the number of subnet packets discarded when data transfer is suspended in Vc recovery.

What is mscRsaConnectionVcNotDataXferFromSubnet?

Counts subnet packets discarded because data transfer was suspended while the Vc was in recovery, the receive-side counterpart to mscRsaConnectionVcNotDataXferToSubnet.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.108.4.2.12.1.8
snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-ServerAccessRsaMIB::mscRsaConnectionVcNotDataXferFromSubnet

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.108.4.2.12.1.8.1
snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-ServerAccessRsaMIB::mscRsaConnectionVcNotDataXferFromSubnet.1

Start monitoring Nortel MsCarrier/Magellan Passport switch (RSA SecurID admin access) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-ServerAccessRsaMIB::mscRsaConnectionVcNotDataXferFromSubnet OID value, configure state conditions and alerts, and monitor any Nortel MsCarrier/Magellan Passport switch (RSA SecurID admin access) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.562nortelCPM-NORTEL-MIB
1.3.6.1.4.1.562.36msCarrierNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2mscPassportNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2.1mscComponentsNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
Numeric OIDNameModule
1.3.6.1.4.1.562.36.2.1.108mscRsaNortel-MsCarrier-MscPassport-ServerAccessRsaMIB
1.3.6.1.4.1.562.36.2.1.108.4mscRsaConnectionNortel-MsCarrier-MscPassport-ServerAccessRsaMIB
1.3.6.1.4.1.562.36.2.1.108.4.2mscRsaConnectionVcNortel-MsCarrier-MscPassport-ServerAccessRsaMIB
1.3.6.1.4.1.562.36.2.1.108.4.2.12mscRsaConnectionVcFrdTableNortel-MsCarrier-MscPassport-ServerAccessRsaMIB
1.3.6.1.4.1.562.36.2.1.108.4.2.12.1mscRsaConnectionVcFrdEntryNortel-MsCarrier-MscPassport-ServerAccessRsaMIB
1.3.6.1.4.1.562.36.2.1.108.4.2.12.1.8mscRsaConnectionVcNotDataXferFromSubnetNortel-MsCarrier-MscPassport-ServerAccessRsaMIB