Nortel-MsCarrier-MscPassport-ServerAccessRsaMIB :: mscRsaConnectionVcCombErrorsFromSubnet

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › Nortel-MsCarrier-MscPassport-ServerAccessRsaMIB › mscRsaConnectionVcCombErrorsFromSubnet

mscRsaConnectionVcCombErrorsFromSubnet

Module: Nortel-MsCarrier-MscPassport-ServerAccessRsaMIB

OID (symbolic): Nortel-MsCarrier-MscPassport-ServerAccessRsaMIB::mscRsaConnectionVcCombErrorsFromSubnet

OID (numeric): 1.3.6.1.4.1.562.36.2.1.108.4.2.12.1.6

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-only

Description: This attribute records the number of subnet packets discarded at the sink Vc due to the Vc segmentation and combination protocol error. Usually, this occurs when the subnet discards packets and thus this statistics can be used to guest the number of subnet packets that are not delivered to the Vc. It cannot be used as an actual measure because some subnet packets may have been delivered to Vc but have to be discarded because these are partial packets to a frame in which some other partial packets have not been properly delivered to Vc

What is mscRsaConnectionVcCombErrorsFromSubnet?

Counts subnet packets discarded at the sink Vc due to a segmentation/combination protocol error, most often a symptom of the subnet having discarded some packets upstream; not a fully precise measure since some counted packets may have partially arrived before being discarded as incomplete frames.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.108.4.2.12.1.6
snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-ServerAccessRsaMIB::mscRsaConnectionVcCombErrorsFromSubnet

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.108.4.2.12.1.6.1
snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-ServerAccessRsaMIB::mscRsaConnectionVcCombErrorsFromSubnet.1

Start monitoring Nortel MsCarrier/Magellan Passport switch (RSA SecurID admin access) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-ServerAccessRsaMIB::mscRsaConnectionVcCombErrorsFromSubnet OID value, configure state conditions and alerts, and monitor any Nortel MsCarrier/Magellan Passport switch (RSA SecurID admin access) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.562nortelCPM-NORTEL-MIB
1.3.6.1.4.1.562.36msCarrierNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2mscPassportNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2.1mscComponentsNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
Numeric OIDNameModule
1.3.6.1.4.1.562.36.2.1.108mscRsaNortel-MsCarrier-MscPassport-ServerAccessRsaMIB
1.3.6.1.4.1.562.36.2.1.108.4mscRsaConnectionNortel-MsCarrier-MscPassport-ServerAccessRsaMIB
1.3.6.1.4.1.562.36.2.1.108.4.2mscRsaConnectionVcNortel-MsCarrier-MscPassport-ServerAccessRsaMIB
1.3.6.1.4.1.562.36.2.1.108.4.2.12mscRsaConnectionVcFrdTableNortel-MsCarrier-MscPassport-ServerAccessRsaMIB
1.3.6.1.4.1.562.36.2.1.108.4.2.12.1mscRsaConnectionVcFrdEntryNortel-MsCarrier-MscPassport-ServerAccessRsaMIB
1.3.6.1.4.1.562.36.2.1.108.4.2.12.1.6mscRsaConnectionVcCombErrorsFromSubnetNortel-MsCarrier-MscPassport-ServerAccessRsaMIB