Module: Nortel-MsCarrier-MscPassport-LogicalProcessorMIB

OID (symbolic): Nortel-MsCarrier-MscPassport-LogicalProcessorMIB::mscLpV35LinkMode

OID (numeric): 1.3.6.1.4.1.562.36.2.1.12.9.10.1.1

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: This attribute defines the intended gender of the V.35 interface. The actual gender of the interface is determined by the physical connection to the patch panel. If the hardware setup does not match this attribute, an alarm will be generated.

In dte mode, the RTS line signal is driven as specified by the attribute readyLineState when the interface passes its initial diagnostics. Then, the RTS line signal will be driven as specified in the attribute dataTransferLineState when the application is ready to transfer data. On the other hand, the input line signals (RFS, DSR, and DCD) are compared against those specified in the attributes readyLineState and dataTransferLineState. The application will be notified when the specified input line states are observed.

In dce mode, the V35 component behaves similarly as when it is in dte mode. However, it will be driving the DCE line signals (RFS, DSR, and DCD) and monitoring the DTE line signal (RTS) as specified by the attributes readyLineState and dataTransferLineState.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.12.9.10.1.1
snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-LogicalProcessorMIB::mscLpV35LinkMode

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.12.9.10.1.1.1
snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-LogicalProcessorMIB::mscLpV35LinkMode.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.562.36.2.1.12.9.10.1.1.1 i <value>

Start monitoring Nortel MsCarrier MscPassport switch (logical processor/card redundancy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-LogicalProcessorMIB::mscLpV35LinkMode OID value, configure state conditions and alerts, and monitor any Nortel MsCarrier MscPassport switch (logical processor/card redundancy) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.562nortelCPM-NORTEL-MIB
1.3.6.1.4.1.562.36msCarrierNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2mscPassportNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2.1mscComponentsNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
Numeric OIDNameModule
1.3.6.1.4.1.562.36.2.1.12mscLpNortel-MsCarrier-MscPassport-LogicalProcessorMIB
1.3.6.1.4.1.562.36.2.1.12.9mscLpV35Nortel-MsCarrier-MscPassport-LogicalProcessorMIB
1.3.6.1.4.1.562.36.2.1.12.9.10mscLpV35ProvTableNortel-MsCarrier-MscPassport-LogicalProcessorMIB
1.3.6.1.4.1.562.36.2.1.12.9.10.1mscLpV35ProvEntryNortel-MsCarrier-MscPassport-LogicalProcessorMIB
1.3.6.1.4.1.562.36.2.1.12.9.10.1.1mscLpV35LinkModeNortel-MsCarrier-MscPassport-LogicalProcessorMIB