Nortel-MsCarrier-MscPassport-LogicalProcessorMIB :: mscLpSdhPathRxRfiAlarm

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › Nortel-MsCarrier-MscPassport-LogicalProcessorMIB › mscLpSdhPathRxRfiAlarm

mscLpSdhPathRxRfiAlarm

Module: Nortel-MsCarrier-MscPassport-LogicalProcessorMIB

OID (symbolic): Nortel-MsCarrier-MscPassport-LogicalProcessorMIB::mscLpSdhPathRxRfiAlarm

OID (numeric): 1.3.6.1.4.1.562.36.2.1.12.15.2.15.1.3

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: This attribute displays whether the Path Remote Failure Indication (P-RFI) alarm state has been entered. An P-RFI alarm state is entered when Path Remote Defect Indicator (P-RDI) defects have been observed and accumulated for a period of 2.5 seconds +/- 0.5 seconds. The P-RDI defect is the occurrence of the P-RDI signal in five contiguous valid STS or STM frames (bit 5 of the G1 byte set to 1). If the P-RDI defects are intermittently occurring, the P-RDI defect accumulator is decremented at a rate of 1/10 of the incrementing rate (alarm integration ratio of 1/10)with all measurements based on a 200 ms polling cycle. The Path component goes into an operational state of disabled until the P-RFI alarm condition is cleared. The condition is cleared after no P-RDI defect has been detected for 10 seconds +/- 0.5 seconds. The rxRfiAlarm attribute is always set to off when the Path component has been locked and left offline by the operator or when the Path component has been suspended since the parent component has been locked.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.12.15.2.15.1.3
snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-LogicalProcessorMIB::mscLpSdhPathRxRfiAlarm

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.12.15.2.15.1.3.1
snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-LogicalProcessorMIB::mscLpSdhPathRxRfiAlarm.1

Start monitoring Nortel MsCarrier MscPassport switch (logical processor/card redundancy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-LogicalProcessorMIB::mscLpSdhPathRxRfiAlarm OID value, configure state conditions and alerts, and monitor any Nortel MsCarrier MscPassport switch (logical processor/card redundancy) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.562nortelCPM-NORTEL-MIB
1.3.6.1.4.1.562.36msCarrierNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2mscPassportNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2.1mscComponentsNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
Numeric OIDNameModule
1.3.6.1.4.1.562.36.2.1.12mscLpNortel-MsCarrier-MscPassport-LogicalProcessorMIB
1.3.6.1.4.1.562.36.2.1.12.15mscLpSdhNortel-MsCarrier-MscPassport-LogicalProcessorMIB
1.3.6.1.4.1.562.36.2.1.12.15.2mscLpSdhPathNortel-MsCarrier-MscPassport-LogicalProcessorMIB
1.3.6.1.4.1.562.36.2.1.12.15.2.15mscLpSdhPathOperTableNortel-MsCarrier-MscPassport-LogicalProcessorMIB
1.3.6.1.4.1.562.36.2.1.12.15.2.15.1mscLpSdhPathOperEntryNortel-MsCarrier-MscPassport-LogicalProcessorMIB
1.3.6.1.4.1.562.36.2.1.12.15.2.15.1.3mscLpSdhPathRxRfiAlarmNortel-MsCarrier-MscPassport-LogicalProcessorMIB