All MIBs › Nortel-MsCarrier-MscPassport-LogicalProcessorMIB › mscLpJT2RxRaiAlarm
mscLpJT2RxRaiAlarm
Module: Nortel-MsCarrier-MscPassport-LogicalProcessorMIB
OID (symbolic): Nortel-MsCarrier-MscPassport-LogicalProcessorMIB::mscLpJT2RxRaiAlarm
OID (numeric): 1.3.6.1.4.1.562.36.2.1.12.16.15.1.5
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: This attribute indicates whether a Received RAI alarm state is entered. A received RAI alarm state is entered when the RAI signal is detected on the incoming JT2 Line (when 16 or more consecutive RAI patterns of 1111111100000000 are received on the 4 kbit/s data channel (m-bits) within the framing bits of the JT2 frame). The JT2 port goes into an operationalState of Disabled until the RAI alarm condition is cleared. The RAI alarm is cleared when four or more consecutive non-RAI patterns (anything other than 1111111100000000) are received.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.12.16.15.1.5 snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-LogicalProcessorMIB::mscLpJT2RxRaiAlarm
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.12.16.15.1.5.1 snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-LogicalProcessorMIB::mscLpJT2RxRaiAlarm.1
Start monitoring Nortel MsCarrier MscPassport switch (logical processor/card redundancy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-LogicalProcessorMIB::mscLpJT2RxRaiAlarm OID value, configure state conditions and alerts, and monitor any Nortel MsCarrier MscPassport switch (logical processor/card redundancy) from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.562 | nortel | CPM-NORTEL-MIB |
| 1.3.6.1.4.1.562.36 | msCarrier | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2 | mscPassport | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2.1 | mscComponents | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.562.36.2.1.12 | mscLp | Nortel-MsCarrier-MscPassport-LogicalProcessorMIB |
| 1.3.6.1.4.1.562.36.2.1.12.16 | mscLpJT2 | Nortel-MsCarrier-MscPassport-LogicalProcessorMIB |
| 1.3.6.1.4.1.562.36.2.1.12.16.15 | mscLpJT2OperTable | Nortel-MsCarrier-MscPassport-LogicalProcessorMIB |
| 1.3.6.1.4.1.562.36.2.1.12.16.15.1 | mscLpJT2OperEntry | Nortel-MsCarrier-MscPassport-LogicalProcessorMIB |
| 1.3.6.1.4.1.562.36.2.1.12.16.15.1.5 | mscLpJT2RxRaiAlarm | Nortel-MsCarrier-MscPassport-LogicalProcessorMIB |