Nortel-MsCarrier-MscPassport-FrameRelayMuxMIB :: mscFrMuxLmiProcedures

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › Nortel-MsCarrier-MscPassport-FrameRelayMuxMIB › mscFrMuxLmiProcedures

mscFrMuxLmiProcedures

Module: Nortel-MsCarrier-MscPassport-FrameRelayMuxMIB

OID (symbolic): Nortel-MsCarrier-MscPassport-FrameRelayMuxMIB::mscFrMuxLmiProcedures

OID (numeric): 1.3.6.1.4.1.562.36.2.1.112.3.10.1.1

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: This attribute selects the procedures to be used for the Local Management Interface. The following are the supported procedures: none : No Local Management Interface procedure is active. vendorForum : Local Management Interface procedure according to the Vendor Forum specification is active. DLCI 1023 is used for the LMI protocol. ansi: Local Management Interface procedure according to the ANSI specification is active. DLCI 0 is used for the LMI protocol. ccitt: Local Management Interface procedure according to the CCITT specification is active. DLCI 0 is used for the LMI protocol.

What is mscFrMuxLmiProcedures?

Selects which Frame Relay Local Management Interface signaling standard is used on this link — none, vendorForum (DLCI 1023), ansi, or ccitt (the default, DLCI 0) — both ends of the Frame Relay circuit must agree on this setting or LMI status polling will fail.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.112.3.10.1.1
snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-FrameRelayMuxMIB::mscFrMuxLmiProcedures

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.112.3.10.1.1.1
snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-FrameRelayMuxMIB::mscFrMuxLmiProcedures.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.562.36.2.1.112.3.10.1.1.1 i <value>

Start monitoring Nortel Networks MscPassport carrier switching platform (Frame Relay multiplexer/DLCI) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-FrameRelayMuxMIB::mscFrMuxLmiProcedures OID value, configure state conditions and alerts, and monitor any Nortel Networks MscPassport carrier switching platform (Frame Relay multiplexer/DLCI) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.562nortelCPM-NORTEL-MIB
1.3.6.1.4.1.562.36msCarrierNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2mscPassportNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2.1mscComponentsNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
Numeric OIDNameModule
1.3.6.1.4.1.562.36.2.1.112mscFrMuxNortel-MsCarrier-MscPassport-FrameRelayMuxMIB
1.3.6.1.4.1.562.36.2.1.112.3mscFrMuxLmiNortel-MsCarrier-MscPassport-FrameRelayMuxMIB
1.3.6.1.4.1.562.36.2.1.112.3.10mscFrMuxLmiProvTableNortel-MsCarrier-MscPassport-FrameRelayMuxMIB
1.3.6.1.4.1.562.36.2.1.112.3.10.1mscFrMuxLmiProvEntryNortel-MsCarrier-MscPassport-FrameRelayMuxMIB
1.3.6.1.4.1.562.36.2.1.112.3.10.1.1mscFrMuxLmiProceduresNortel-MsCarrier-MscPassport-FrameRelayMuxMIB