Nortel-MsCarrier-MscPassport-FrameRelayDteMIB :: mscFrDteLmiMonitoredEvents

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › Nortel-MsCarrier-MscPassport-FrameRelayDteMIB › mscFrDteLmiMonitoredEvents

mscFrDteLmiMonitoredEvents

Module: Nortel-MsCarrier-MscPassport-FrameRelayDteMIB

OID (symbolic): Nortel-MsCarrier-MscPassport-FrameRelayDteMIB::mscFrDteLmiMonitoredEvents

OID (numeric): 1.3.6.1.4.1.562.36.2.1.101.3.10.1.7

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-write

Description: The number of status polling intervals over which the errorthreshold is counted This is used to determine if the errorThreshold is exceeded. This field corresponds to the parameter N393 described in the ANSI T1.617-1991 Annex D.

What is mscFrDteLmiMonitoredEvents?

The number of status polling intervals over which the errorthreshold is counted This is used to determine if the errorThreshold is exceeded. This field corresponds to the parameter N393 described in the ANSI T1.617-1991 Annex D. An admin only needs to change this from its default if the carrier's Frame Relay switch requires a non-standard LMI timing profile; setting it too aggressively can make the link flag false LMI failures.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.101.3.10.1.7
snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-FrameRelayDteMIB::mscFrDteLmiMonitoredEvents

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.101.3.10.1.7.1
snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-FrameRelayDteMIB::mscFrDteLmiMonitoredEvents.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.562.36.2.1.101.3.10.1.7.1 i <value>

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> mscFrDteLmiMonitoredEvents.1

Start monitoring Nortel MscPassport multiservice switch (Frame Relay DTE/DLCI) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-FrameRelayDteMIB::mscFrDteLmiMonitoredEvents OID value, configure state conditions and alerts, and monitor any Nortel MscPassport multiservice switch (Frame Relay DTE/DLCI) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.562nortelCPM-NORTEL-MIB
1.3.6.1.4.1.562.36msCarrierNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2mscPassportNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2.1mscComponentsNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
Numeric OIDNameModule
1.3.6.1.4.1.562.36.2.1.101mscFrDteNortel-MsCarrier-MscPassport-FrameRelayDteMIB
1.3.6.1.4.1.562.36.2.1.101.3mscFrDteLmiNortel-MsCarrier-MscPassport-FrameRelayDteMIB
1.3.6.1.4.1.562.36.2.1.101.3.10mscFrDteLmiProvTableNortel-MsCarrier-MscPassport-FrameRelayDteMIB
1.3.6.1.4.1.562.36.2.1.101.3.10.1mscFrDteLmiProvEntryNortel-MsCarrier-MscPassport-FrameRelayDteMIB
1.3.6.1.4.1.562.36.2.1.101.3.10.1.7mscFrDteLmiMonitoredEventsNortel-MsCarrier-MscPassport-FrameRelayDteMIB